Experimental verification of stopping-power prediction from single- and dual-energy computed tomography in biological tissues. (9th January 2018)
- Record Type:
- Journal Article
- Title:
- Experimental verification of stopping-power prediction from single- and dual-energy computed tomography in biological tissues. (9th January 2018)
- Main Title:
- Experimental verification of stopping-power prediction from single- and dual-energy computed tomography in biological tissues
- Authors:
- Möhler, Christian
Russ, Tom
Wohlfahrt, Patrick
Elter, Alina
Runz, Armin
Richter, Christian
Greilich, Steffen - Abstract:
- Abstract: An experimental setup for consecutive measurement of ion and x-ray absorption in tissue or other materials is introduced. With this setup using a 3D-printed sample container, the reference stopping-power ratio (SPR) of materials can be measured with an uncertainty of below 0.1%. A total of 65 porcine and bovine tissue samples were prepared for measurement, comprising five samples each of 13 tissue types representing about 80% of the total body mass (three different muscle and fatty tissues, liver, kidney, brain, heart, blood, lung and bone). Using a standard stoichiometric calibration for single-energy CT (SECT) as well as a state-of-the-art dual-energy CT (DECT) approach, SPR was predicted for all tissues and then compared to the measured reference. With the SECT approach, the SPRs of all tissues were predicted with a mean error of (−0.84 ± 0.12)% and a mean absolute error of (1.27 ± 0.12)%. In contrast, the DECT-based SPR predictions were overall consistent with the measured reference with a mean error of (−0.02 ± 0.15)% and a mean absolute error of (0.10 ± 0.15)%. Thus, in this study, the potential of DECT to decrease range uncertainty could be confirmed in biological tissue.
- Is Part Of:
- Physics in medicine & biology. Volume 63:Number 2(2018:Jan.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 63:Number 2(2018:Jan.)
- Issue Display:
- Volume 63, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 63
- Issue:
- 2
- Issue Sort Value:
- 2018-0063-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-01-09
- Subjects:
- proton and ion radiation therapy -- treatment planning -- stopping-power ratio -- range verification
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/aaa1c9 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6399.xml