H‐reflex and M‐wave recordings: effect of pressure application to the stimulation electrode on the assessment of evoked potentials and subject's discomfort. (26th April 2017)
- Record Type:
- Journal Article
- Title:
- H‐reflex and M‐wave recordings: effect of pressure application to the stimulation electrode on the assessment of evoked potentials and subject's discomfort. (26th April 2017)
- Main Title:
- H‐reflex and M‐wave recordings: effect of pressure application to the stimulation electrode on the assessment of evoked potentials and subject's discomfort
- Authors:
- Cattagni, Thomas
Merlet, Angèle N.
Cornu, Christophe
Jubeau, Marc - Abstract:
- Summary: This study aimed to compare the effect of different types of pressure applied to the stimulation electrode on assessing the efficiency of Ia‐α‐motoneuron transmission of the soleus muscle and the associated discomfort using electrical nerve stimulation. Twelve healthy young adults participated in three experimental sessions (one for each knee angle). The amplitudes of the maximal Hoffmann reflex ( H max ) and motor potential ( M max ) were recorded from the soleus muscle at 0°, 30° and 90° knee angles (0° full extension) through three pressure applications to the stimulation electrode: no pressure, pressure with manual application and pressure using adhesive tape. The soleus H max / M max were calculated to assess the efficiency of Ia‐α‐motoneuron transmission during varied knee angles and pressure application to the stimulation electrode. At the stimulation intensity evoking soleus H max and M max, subjects were asked to orally provide a value between 'no discomfort' (0) and 'worst possible discomfort' (10). The application of pressure on the stimulation electrode, particularly using adhesive tape, decreased both the stimulation intensity needed to evoke an electrophysiological response and the associated self‐reported discomfort ( P <0·05), while the H max / M max remained constant. At the stimulation intensity evoking M max, the electrical stimulation appeared to be more painful at 0° knee angle compared with 30° and 90° angles ( P <0·01). To conclude, this studySummary: This study aimed to compare the effect of different types of pressure applied to the stimulation electrode on assessing the efficiency of Ia‐α‐motoneuron transmission of the soleus muscle and the associated discomfort using electrical nerve stimulation. Twelve healthy young adults participated in three experimental sessions (one for each knee angle). The amplitudes of the maximal Hoffmann reflex ( H max ) and motor potential ( M max ) were recorded from the soleus muscle at 0°, 30° and 90° knee angles (0° full extension) through three pressure applications to the stimulation electrode: no pressure, pressure with manual application and pressure using adhesive tape. The soleus H max / M max were calculated to assess the efficiency of Ia‐α‐motoneuron transmission during varied knee angles and pressure application to the stimulation electrode. At the stimulation intensity evoking soleus H max and M max, subjects were asked to orally provide a value between 'no discomfort' (0) and 'worst possible discomfort' (10). The application of pressure on the stimulation electrode, particularly using adhesive tape, decreased both the stimulation intensity needed to evoke an electrophysiological response and the associated self‐reported discomfort ( P <0·05), while the H max / M max remained constant. At the stimulation intensity evoking M max, the electrical stimulation appeared to be more painful at 0° knee angle compared with 30° and 90° angles ( P <0·01). To conclude, this study showed that a knee flexion and a pressure application to the stimulation electrode, especially using tape pressure, are recommended in the objective to reduce the patient/subjects' discomfort when eliciting evoked potentials on soleus muscle. … (more)
- Is Part Of:
- Clinical physiology and functional imaging. Volume 38:Number 3(2018:May)
- Journal:
- Clinical physiology and functional imaging
- Issue:
- Volume 38:Number 3(2018:May)
- Issue Display:
- Volume 38, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 38
- Issue:
- 3
- Issue Sort Value:
- 2018-0038-0003-0000
- Page Start:
- 416
- Page End:
- 424
- Publication Date:
- 2017-04-26
- Subjects:
- discomfort -- electrical nerve stimulation -- Hoffmann reflex -- pain -- plantar flexors -- spinal transmission
Physiology, Pathological -- Periodicals
Diagnostic imaging -- Periodicals
612 - Journal URLs:
- http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=cpf ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/cpf.12431 ↗
- Languages:
- English
- ISSNs:
- 1475-0961
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.333520
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6373.xml