Individually adapted tube current selection and contrast medium injection protocol of coronary CT angiography based on test bolus parameters: a feasibility study. (June 2015)
- Record Type:
- Journal Article
- Title:
- Individually adapted tube current selection and contrast medium injection protocol of coronary CT angiography based on test bolus parameters: a feasibility study. (June 2015)
- Main Title:
- Individually adapted tube current selection and contrast medium injection protocol of coronary CT angiography based on test bolus parameters: a feasibility study
- Authors:
- Zhu, Xiaomei
Shi, Zhaofei
Zhu, Yinsu
Liu, Wangyan
Yang, Guanyu
Yu, Tongfu
Tang, Lijun
Xu, Yi - Abstract:
- Background: Test bolus is mostly used to determine the starting point of a full cardiac scanning with respect to injection of a larger bolus of contrast material. So far there are limited data demonstrating the feasibility of using information obtained from a test bolus to adjust contrast delivery protocols and tube current individually during coronary computed tomography angiography (CCTA). Purpose: To evaluate the feasibility of individually adapted tube current selection and contrast injection protocols of CCTA based on test bolus parameters. Material and Methods: Test bolus followed by CCTA was performed in 93 patients at 100 kV and in 81 patients at 120 kV, respectively. Simulated attenuation of the descending aorta (SimDA ) of CCTA was calculated at a fixed contrast injection rate of 4 mL/s. Univariate and multivariate comparisons were performed to identify associations of SimDA and image noise of CCTA (NoiseCCTA ) with test bolus information and patient-related factors including body weight (BW), body mass index (BMI), and body surface area (BSA). Results: Compared with BW, BMI, and BSA, SimDA was more closely related to the peak time of left ventricle and peak enhancement of right ventricle obtained from test bolus ( r = 0.495 and r = 0.642 for 100 and 120 kV protocol, respectively). Similarly, NoiseTB was much more closely related to NoiseCCTA ( r = 0.740 and r = 0.630 for 100 and 120 kV protocol, respectively) when compared with BW, BMI, and BSA. Conclusion: ItBackground: Test bolus is mostly used to determine the starting point of a full cardiac scanning with respect to injection of a larger bolus of contrast material. So far there are limited data demonstrating the feasibility of using information obtained from a test bolus to adjust contrast delivery protocols and tube current individually during coronary computed tomography angiography (CCTA). Purpose: To evaluate the feasibility of individually adapted tube current selection and contrast injection protocols of CCTA based on test bolus parameters. Material and Methods: Test bolus followed by CCTA was performed in 93 patients at 100 kV and in 81 patients at 120 kV, respectively. Simulated attenuation of the descending aorta (SimDA ) of CCTA was calculated at a fixed contrast injection rate of 4 mL/s. Univariate and multivariate comparisons were performed to identify associations of SimDA and image noise of CCTA (NoiseCCTA ) with test bolus information and patient-related factors including body weight (BW), body mass index (BMI), and body surface area (BSA). Results: Compared with BW, BMI, and BSA, SimDA was more closely related to the peak time of left ventricle and peak enhancement of right ventricle obtained from test bolus ( r = 0.495 and r = 0.642 for 100 and 120 kV protocol, respectively). Similarly, NoiseTB was much more closely related to NoiseCCTA ( r = 0.740 and r = 0.630 for 100 and 120 kV protocol, respectively) when compared with BW, BMI, and BSA. Conclusion: It is feasible to individually adapt tube current and contrast injection protocol of CCTA based on the information of test bolus. … (more)
- Is Part Of:
- Acta radiologica. Volume 56:Number 6(2015:Jun.)
- Journal:
- Acta radiologica
- Issue:
- Volume 56:Number 6(2015:Jun.)
- Issue Display:
- Volume 56, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 56
- Issue:
- 6
- Issue Sort Value:
- 2015-0056-0006-0000
- Page Start:
- 666
- Page End:
- 672
- Publication Date:
- 2015-06
- Subjects:
- Coronary CT angiography -- test bolus -- image noise -- contrast enhancement -- descending aorta
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185114536156 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6363.xml