T-piece or self inflating bag for positive pressure ventilation during delivery room resuscitation: An RCT. (May 2015)
- Record Type:
- Journal Article
- Title:
- T-piece or self inflating bag for positive pressure ventilation during delivery room resuscitation: An RCT. (May 2015)
- Main Title:
- T-piece or self inflating bag for positive pressure ventilation during delivery room resuscitation: An RCT
- Authors:
- Thakur, Anup
Saluja, Satish
Modi, Manoj
Kler, Neelam
Garg, Pankaj
Soni, Arun
Kaur, Avneet
Chetri, Sanjeev - Abstract:
- Abstract: Objective: To compare the duration of positive pressure ventilation (PPV) during delivery room resuscitation in neonates resuscitated with self-inflating bag (SIB) and T-piece resuscitator (TPR). Design: Randomized control trial. Setting: Delivery room and neonatal intensive care unit of a tertiary care center in northern India. Patients: Consecutively born neonates more than 26 weeks of gestation requiring PPV at birth. Intervention: Eligible neonates were randomized to two groups, SIB and TPR. Outcome measures: Duration of PPV, intubation rates in delivery room, incidence of respiratory distress, need for mechanical ventilation during first 48 h and its duration, need for surfactant replacement therapy and mortality during NICU stay. Results: Fifty neonates received PPV with a SIB and 40 received PPV with a TPR. The mean (SD) birth weight and gestational age of neonates in SIB and TPR groups were 2264 (872) and 2065 (814) g; 35.1 (3.6) and 34.3 (3.7) weeks, respectively. The median (IQR) duration of PPV in delivery room was significantly less in TPR group as compared to SIB; 30 (30–60) s vs. 60 (30–90) s, respectively; ( p < 0.001). A higher proportion of neonates required delivery room intubation in SIB group as compared to TPR group (34% vs. 15%, p = 0.04). In the TPR group, a higher proportion of neonates could be resuscitated with room air only (72.5% vs. 38%, p = 0.001). Other outcomes were comparable in the two groups. Similar findings were observed inAbstract: Objective: To compare the duration of positive pressure ventilation (PPV) during delivery room resuscitation in neonates resuscitated with self-inflating bag (SIB) and T-piece resuscitator (TPR). Design: Randomized control trial. Setting: Delivery room and neonatal intensive care unit of a tertiary care center in northern India. Patients: Consecutively born neonates more than 26 weeks of gestation requiring PPV at birth. Intervention: Eligible neonates were randomized to two groups, SIB and TPR. Outcome measures: Duration of PPV, intubation rates in delivery room, incidence of respiratory distress, need for mechanical ventilation during first 48 h and its duration, need for surfactant replacement therapy and mortality during NICU stay. Results: Fifty neonates received PPV with a SIB and 40 received PPV with a TPR. The mean (SD) birth weight and gestational age of neonates in SIB and TPR groups were 2264 (872) and 2065 (814) g; 35.1 (3.6) and 34.3 (3.7) weeks, respectively. The median (IQR) duration of PPV in delivery room was significantly less in TPR group as compared to SIB; 30 (30–60) s vs. 60 (30–90) s, respectively; ( p < 0.001). A higher proportion of neonates required delivery room intubation in SIB group as compared to TPR group (34% vs. 15%, p = 0.04). In the TPR group, a higher proportion of neonates could be resuscitated with room air only (72.5% vs. 38%, p = 0.001). Other outcomes were comparable in the two groups. Similar findings were observed in neonates <34 weeks, except that fewer neonates resuscitated with TPR required invasive ventilation (31.6% vs. 77.8%, p = 0.008). Conclusion: Use of TPR during delivery room resuscitation resulted in shorter duration of PPV and lesser rates of intubation as compared to SIB. More infants in this group could be resuscitated with room air only (CTRI/2010/091/002946). … (more)
- Is Part Of:
- Resuscitation. Volume 90(2015)
- Journal:
- Resuscitation
- Issue:
- Volume 90(2015)
- Issue Display:
- Volume 90, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 90
- Issue:
- 2015
- Issue Sort Value:
- 2015-0090-2015-0000
- Page Start:
- 21
- Page End:
- 24
- Publication Date:
- 2015-05
- Subjects:
- CPAP continuous positive airway pressure -- MAP mean airway pressure -- PEEP positive end expiratory pressure -- PPV positive pressure ventilation -- SIB self inflating bag -- TPR T piece resuscitator
Positive end expiratory pressure -- Positive pressure ventilation -- Self inflating bag -- T piece resuscitator
Resuscitation -- Periodicals
Resuscitation -- Periodicals
Réanimation -- Périodiques
Electronic journals
616.025 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03009572 ↗
http://www.resuscitationjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03009572 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03009572 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.resuscitation.2015.01.021 ↗
- Languages:
- English
- ISSNs:
- 0300-9572
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.420000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6357.xml