Variability in reference point microindentation and recommendations for testing cortical bone: Location, thickness and orientation heterogeneity. (June 2015)
- Record Type:
- Journal Article
- Title:
- Variability in reference point microindentation and recommendations for testing cortical bone: Location, thickness and orientation heterogeneity. (June 2015)
- Main Title:
- Variability in reference point microindentation and recommendations for testing cortical bone: Location, thickness and orientation heterogeneity
- Authors:
- Coutts, L.V.
Jenkins, T.
Li, T.
Dunlop, D.G.
Oreffo, R.O.C.
Cooper, C.
Harvey, N.C.
Thurner, P.J. - Abstract:
- Abstract: Reference Point Indentation (RPI) has been proposed as a new clinical tool to aid the diagnosis of Osteoporosis. This study has examined the performance of the tool within entire femurs to improve the understanding of the mechanical properties of bone and also to guide future RPI testing to optimize repeatability of results obtained using the technique. Human, bovine, porcine and rat femurs were indented along three longitudinal axes: anterior and posterior: medial and lateral as well as around the circumference of the femoral head and neck. Cortical and subchondral bone thickness was measured using CT and radiography. The study shows that in some samples, bone is too thin to support the high loads applied with the technique and in these cases, RPI values are highly influenced by thickness. The technique will be useful in the mid-shaft region where cortical thickness is greatest, providing previously established guidelines are followed to optimize measurement repeatability, including performing multiple measurements per sample and investigating multiple samples. The study has also provided evidence that RPI values vary significantly with test site, hence mechanical properties should not be inferred from RPI findings alone away from the test site, even within the same bone. In conclusion, RPI appears to be a useful tool for scientific investigation; however further work is required to examine the feasibility of using RPI for assessing differences between healthy andAbstract: Reference Point Indentation (RPI) has been proposed as a new clinical tool to aid the diagnosis of Osteoporosis. This study has examined the performance of the tool within entire femurs to improve the understanding of the mechanical properties of bone and also to guide future RPI testing to optimize repeatability of results obtained using the technique. Human, bovine, porcine and rat femurs were indented along three longitudinal axes: anterior and posterior: medial and lateral as well as around the circumference of the femoral head and neck. Cortical and subchondral bone thickness was measured using CT and radiography. The study shows that in some samples, bone is too thin to support the high loads applied with the technique and in these cases, RPI values are highly influenced by thickness. The technique will be useful in the mid-shaft region where cortical thickness is greatest, providing previously established guidelines are followed to optimize measurement repeatability, including performing multiple measurements per sample and investigating multiple samples. The study has also provided evidence that RPI values vary significantly with test site, hence mechanical properties should not be inferred from RPI findings alone away from the test site, even within the same bone. In conclusion, RPI appears to be a useful tool for scientific investigation; however further work is required to examine the feasibility of using RPI for assessing differences between healthy and diseased bone in a clinical setting. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 46(2015)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 46(2015)
- Issue Display:
- Volume 46, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 46
- Issue:
- 2015
- Issue Sort Value:
- 2015-0046-2015-0000
- Page Start:
- 292
- Page End:
- 304
- Publication Date:
- 2015-06
- Subjects:
- Microindentation -- Reference point indentation -- Bone quality -- Homogeneity -- Femur
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2015.02.004 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6355.xml