Inter-session reliability of short-interval intracortical inhibition measured by threshold tracking TMS. (1st May 2018)
- Record Type:
- Journal Article
- Title:
- Inter-session reliability of short-interval intracortical inhibition measured by threshold tracking TMS. (1st May 2018)
- Main Title:
- Inter-session reliability of short-interval intracortical inhibition measured by threshold tracking TMS
- Authors:
- Matamala, José Manuel
Howells, James
Dharmadasa, Thanuja
Trinh, Terry
Ma, Yan
Lera, Lydia
Vucic, Steve
Burke, David
Kiernan, Matthew C. - Abstract:
- Highlights: Absolute and relative reliability of SICI using TT-TMS was determined. TT-TMS measures were less variable when tests were undertaken at the same time of day. Averaged SICI is the most reproducible TT-TMS variable, and has an excellent ICC. Abstract: Paired-pulse transcranial magnetic stimulation (TMS) using fixed test stimuli suffers from marked variability of the motor evoked potential (MEP) amplitude. Threshold tracking TMS (TT-TMS) was introduced to overcome this problem. The aim of this work was to describe the absolute and relative reliability of short-interval intracortical inhibition (SICI) using TT-TMS. Cortical excitability studies were performed on twenty-six healthy subjects over three sessions (two recordings on the same day and one seven days apart), with MEPs recorded over abductor pollicis brevis. Reliability was established by calculating the standard error of the measurements (SEm), minimal detectable change (MDC) and intraclass correlation coefficient (ICC). Resting motor threshold and averaged SICI presented the lowest SEm and highest ICCs. SICI at 1 ms showed a higher SEm than SICI at 3 ms, suggesting different physiological processes, but averaging SICI over a number of intervals greatly increases the reproducibility. The variability was lower for tests undertaken at the same time of day seven days apart compared to tests performed on the same day, and in both instances the ICC for averaged SICI was ≥0.81. The MDC in averaged SICI was reducedHighlights: Absolute and relative reliability of SICI using TT-TMS was determined. TT-TMS measures were less variable when tests were undertaken at the same time of day. Averaged SICI is the most reproducible TT-TMS variable, and has an excellent ICC. Abstract: Paired-pulse transcranial magnetic stimulation (TMS) using fixed test stimuli suffers from marked variability of the motor evoked potential (MEP) amplitude. Threshold tracking TMS (TT-TMS) was introduced to overcome this problem. The aim of this work was to describe the absolute and relative reliability of short-interval intracortical inhibition (SICI) using TT-TMS. Cortical excitability studies were performed on twenty-six healthy subjects over three sessions (two recordings on the same day and one seven days apart), with MEPs recorded over abductor pollicis brevis. Reliability was established by calculating the standard error of the measurements (SEm), minimal detectable change (MDC) and intraclass correlation coefficient (ICC). Resting motor threshold and averaged SICI presented the lowest SEm and highest ICCs. SICI at 1 ms showed a higher SEm than SICI at 3 ms, suggesting different physiological processes, but averaging SICI over a number of intervals greatly increases the reproducibility. The variability was lower for tests undertaken at the same time of day seven days apart compared to tests performed on the same day, and in both instances the ICC for averaged SICI was ≥0.81. The MDC in averaged SICI was reduced from 6.7% to 2% if the number of subjects was increased from one to eleven. In conclusion, averaged SICI is the most reproducible variable across paired-pulse TT-TMS measures, showing an excellent ICC. It is recommended that, in longitudinal studies, testing be performed at the same time of day and that changes in cortical excitability should be measured and averaged over a number of interstimulus intervals to minimise variability. … (more)
- Is Part Of:
- Neuroscience letters. Volume 674(2018)
- Journal:
- Neuroscience letters
- Issue:
- Volume 674(2018)
- Issue Display:
- Volume 674, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 674
- Issue:
- 2018
- Issue Sort Value:
- 2018-0674-2018-0000
- Page Start:
- 18
- Page End:
- 23
- Publication Date:
- 2018-05-01
- Subjects:
- Reliability -- Minimal detectable changes -- Threshold tracking transcranial magnetic stimulation -- Motor evoked potentials -- Short-interval intracortical inhibition
Neurology -- Periodicals
Neurology -- Periodicals
Research -- Periodicals
Neurologie -- Périodiques
Neuroanatomie -- Périodiques
Neuropharmacologie -- Périodiques
Neurophysiologie -- Périodiques
Neurology
Periodicals
Electronic journals
617.48 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03043940 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.neulet.2018.02.065 ↗
- Languages:
- English
- ISSNs:
- 0304-3940
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.562000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6330.xml