Resting-state networks in healthy adult subjects: a comparison between a 32-element and an 8-element phased array head coil at 3.0 Tesla. (May 2015)
- Record Type:
- Journal Article
- Title:
- Resting-state networks in healthy adult subjects: a comparison between a 32-element and an 8-element phased array head coil at 3.0 Tesla. (May 2015)
- Main Title:
- Resting-state networks in healthy adult subjects: a comparison between a 32-element and an 8-element phased array head coil at 3.0 Tesla
- Authors:
- Paolini, Marco
Keeser, Daniel
Ingrisch, Michael
Werner, Natalie
Kindermann, Nicole
Reiser, Maximilian
Blautzik, Janusch - Abstract:
- Background: Little research exists on the influence of a magnetic resonance imaging (MRI) head coil's channel count on measured resting-state functional connectivity. Purpose: To compare a 32-element (32ch) and an 8-element (8ch) phased array head coil with respect to their potential to detect functional connectivity within resting-state networks. Material and Methods: Twenty-six healthy adults (mean age, 21.7 years; SD, 2.1 years) underwent resting-state functional MRI at 3.0 Tesla with both coils using equal standard imaging parameters and a counterbalanced design. Independent component analysis (ICA) at different model orders and a dual regression approach were performed. Voxel-wise non-parametric statistical between-group contrasts were determined using permutation-based non-parametric inference. Results: Phantom measurements demonstrated a generally higher image signal-to-noise ratio using the 32ch head coil. However, the results showed no significant differences between corresponding resting-state networks derived from both coils ( p < 0.05, FWE-corrected). Conclusion: Using the identical standard acquisition parameters, the 32ch head coil does not offer any significant advantages in detecting ICA-based functional connectivity within RSNs.
- Is Part Of:
- Acta radiologica. Volume 56:Number 5(2015:May)
- Journal:
- Acta radiologica
- Issue:
- Volume 56:Number 5(2015:May)
- Issue Display:
- Volume 56, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 56
- Issue:
- 5
- Issue Sort Value:
- 2015-0056-0005-0000
- Page Start:
- 605
- Page End:
- 613
- Publication Date:
- 2015-05
- Subjects:
- CNS -- magnetic resonance functional imaging -- functional connectivity -- equipment -- phantom study -- signal-to-noise ratio
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185114567703 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6330.xml