Indirect MRI of 17o‐labeled water using steady‐state sequences: Signal simulation and preclinical experiment. Issue 5 (31st August 2017)
- Record Type:
- Journal Article
- Title:
- Indirect MRI of 17o‐labeled water using steady‐state sequences: Signal simulation and preclinical experiment. Issue 5 (31st August 2017)
- Main Title:
- Indirect MRI of 17o‐labeled water using steady‐state sequences: Signal simulation and preclinical experiment
- Authors:
- Kudo, Kohsuke
Harada, Taisuke
Kameda, Hiroyuki
Uwano, Ikuko
Yamashita, Fumio
Higuchi, Satomi
Yoshioka, Kunihiro
Sasaki, Makoto - Abstract:
- Abstract : BACKGROUND: Few studies have been reported for T2 ‐weighted indirect 17 O imaging. PURPOSE/HYPOTHESIS: To evaluate the feasibility of steady‐state sequences for indirect 17 O brain imaging. STUDY TYPE: Signal simulation, phantom measurements, and prospective animal experiments were performed in accordance with the institutional guidelines for animal experiments. POPULATION/SUBJECTS/PHANTOM/SPECIMEN/ANIMAL MODEL: Signal simulations of balanced steady‐state free precession (bSSFP) were performed for concentrations of 17 O ranging from 0.037–1.600%. Phantom measurements with concentrations of 17 O water ranging from 0.037–1.566% were also conducted. Six healthy beagle dogs were scanned with intravenous administration of 20% 17 O‐labeled water (1 mL/kg). FIELD STRENGTH/SEQUENCE: Dynamic 3D‐bSSFP scans were performed at 3T MRI. 17 O‐labeled water was injected 60 seconds after the scan start, and the total scan duration was 5 minutes. ASSESSMENT: Based on the result of signal simulation and phantom measurement, signal changes in the beagle dogs were measured and converted into 17 O concentrations. STATISTICAL TESTS: The 17 O concentrations were averaged for every 15 seconds, and compared to the baseline (30–45 sec) with Dunnett's multiple comparison tests. RESULTS: Signal simulation revealed that the relationships between 17 O concentration and the natural logarithm of relative signals were linear. The intraclass correlation coefficient between relative signals inAbstract : BACKGROUND: Few studies have been reported for T2 ‐weighted indirect 17 O imaging. PURPOSE/HYPOTHESIS: To evaluate the feasibility of steady‐state sequences for indirect 17 O brain imaging. STUDY TYPE: Signal simulation, phantom measurements, and prospective animal experiments were performed in accordance with the institutional guidelines for animal experiments. POPULATION/SUBJECTS/PHANTOM/SPECIMEN/ANIMAL MODEL: Signal simulations of balanced steady‐state free precession (bSSFP) were performed for concentrations of 17 O ranging from 0.037–1.600%. Phantom measurements with concentrations of 17 O water ranging from 0.037–1.566% were also conducted. Six healthy beagle dogs were scanned with intravenous administration of 20% 17 O‐labeled water (1 mL/kg). FIELD STRENGTH/SEQUENCE: Dynamic 3D‐bSSFP scans were performed at 3T MRI. 17 O‐labeled water was injected 60 seconds after the scan start, and the total scan duration was 5 minutes. ASSESSMENT: Based on the result of signal simulation and phantom measurement, signal changes in the beagle dogs were measured and converted into 17 O concentrations. STATISTICAL TESTS: The 17 O concentrations were averaged for every 15 seconds, and compared to the baseline (30–45 sec) with Dunnett's multiple comparison tests. RESULTS: Signal simulation revealed that the relationships between 17 O concentration and the natural logarithm of relative signals were linear. The intraclass correlation coefficient between relative signals in phantom measurement and signal simulations was 0.974. In the animal experiments, significant increases in 17 O concentration ( P < 0.05) were observed 60 seconds after the injection of 17 O. At the end of scanning, mean respective 17 O concentrations of 0.084 ± 0.026%, 0.117 ± 0.038, 0.082 ± 0.037%, and 0.049 ± 0.004% were noted for the cerebral cortex, cerebellar cortex, cerebral white matter, and ventricle. DATA CONCLUSION: Dynamic steady‐state sequences were feasible for indirect 17 O imaging, and absolute quantification was possible. This method can be applied for the measurement of permeability and blood flow in the brain, and for kinetic analysis of cerebrospinal fluid. Level of Evidence : 2 Technical Efficacy : Stage 1 J. Magn. Reson. Imaging 2018;47:1373–1379. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 47:Issue 5(2018)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 47:Issue 5(2018)
- Issue Display:
- Volume 47, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 47
- Issue:
- 5
- Issue Sort Value:
- 2018-0047-0005-0000
- Page Start:
- 1373
- Page End:
- 1379
- Publication Date:
- 2017-08-31
- Subjects:
- animal study -- O‐17 -- phantom measurement -- signal simulation -- steady state sequence
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25848 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6329.xml