Female Stress Urinary Incontinence: Clinical Efficacy and Satisfaction After Transobturator Adjustable Tape Sling. An Observational Longitudinal Cohort Study. (April 2015)
- Record Type:
- Journal Article
- Title:
- Female Stress Urinary Incontinence: Clinical Efficacy and Satisfaction After Transobturator Adjustable Tape Sling. An Observational Longitudinal Cohort Study. (April 2015)
- Main Title:
- Female Stress Urinary Incontinence
- Authors:
- Patrelli, Tito Silvio
Gizzo, Salvatore
Noventa, Marco
Dall'Asta, Andrea
Musarò, Andrea
Faioli, Raffaele
Zanni, Giuliano Carlo
Piantelli, Giovanni
Lukanovic, Adolf
Bacchi Modena, Alberto
Berretta, Roberto - Abstract:
- We performed an observational longitudinal cohort study on patients affected by stress urinary incontinence (SUI) and surgically treated with a transobturator adjustable tape sling (TOA) in order to evaluate this surgical procedure in terms of efficacy, safety, quality of life (QoL) improvement, and patient satisfaction. For all patients, we recorded: general features, preoperative SUI risk factors, obstetrics history, preoperative urodynamic tests, intraoperative/postoperative complications, number of postoperative sling regulations, postmicturition residue, and hospital stay. All patients were asked to complete the validated short version of the Urogenital Distress Inventory (UDI-6) questionnaire 18 months after discharge to evaluate the efficacy of the TOA system. We added 2 adjunctive items to the UDI-6 in order to evaluate patient satisfaction and QoL. All 77 surgical procedures were performed under locoregional anesthesia without complications. Postoperative TOA regulations were performed in 46.8% of patients immediately after the procedure and in 14.3% during hospitalization. Before discharge, postmicturition residue was negative in 67 cases and less than 50 cc in 10 cases. Mean hospital stay was 2.18 days. From the questionnaire evaluation, we found that after the procedure, 90.9% of patients showed a complete regression of urinary symptoms, 1.3% obtained considerable relief from preoperative symptoms, and 6.6% reported poor or absent symptom improvements; 75.3% ofWe performed an observational longitudinal cohort study on patients affected by stress urinary incontinence (SUI) and surgically treated with a transobturator adjustable tape sling (TOA) in order to evaluate this surgical procedure in terms of efficacy, safety, quality of life (QoL) improvement, and patient satisfaction. For all patients, we recorded: general features, preoperative SUI risk factors, obstetrics history, preoperative urodynamic tests, intraoperative/postoperative complications, number of postoperative sling regulations, postmicturition residue, and hospital stay. All patients were asked to complete the validated short version of the Urogenital Distress Inventory (UDI-6) questionnaire 18 months after discharge to evaluate the efficacy of the TOA system. We added 2 adjunctive items to the UDI-6 in order to evaluate patient satisfaction and QoL. All 77 surgical procedures were performed under locoregional anesthesia without complications. Postoperative TOA regulations were performed in 46.8% of patients immediately after the procedure and in 14.3% during hospitalization. Before discharge, postmicturition residue was negative in 67 cases and less than 50 cc in 10 cases. Mean hospital stay was 2.18 days. From the questionnaire evaluation, we found that after the procedure, 90.9% of patients showed a complete regression of urinary symptoms, 1.3% obtained considerable relief from preoperative symptoms, and 6.6% reported poor or absent symptom improvements; 75.3% of patients were totally satisfied and 5.2% totally disappointed. The possibility of modulating postoperative sling tension and reusing the surgical materials in association with short hospitalization as well as high patient satisfaction render TOA a safe, effective, and low-cost technique for the treatment of female SUI. … (more)
- Is Part Of:
- Surgical innovation. Volume 22:Number 2(2015:Apr.)
- Journal:
- Surgical innovation
- Issue:
- Volume 22:Number 2(2015:Apr.)
- Issue Display:
- Volume 22, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 22
- Issue:
- 2
- Issue Sort Value:
- 2015-0022-0002-0000
- Page Start:
- 137
- Page End:
- 142
- Publication Date:
- 2015-04
- Subjects:
- transobturator adjustable tape -- stress urinary incontinence -- quality of life -- patient satisfaction -- UDI-6 questionnaire
Surgery, Operative -- Periodicals
Endoscopic surgery -- Periodicals
Laparoscopic surgery -- Periodicals
Surgical Procedures, Operative -- Periodicals
Surgical Procedures, Minimally Invasive -- Periodicals
Diffusion of Innovation -- Periodicals
Chirurgie opératoire -- Périodiques
Chirurgie endoscopique -- Périodiques
Chirurgie laparoscopique -- Périodiques
617.91 - Journal URLs:
- http://journals.sagepub.com/home/sri ↗
http://sri.sagepub.com/ ↗
http://www.sagepub.com/journalsProdDesc.nav?prodId=Journal201793 ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/1553350614535855 ↗
- Languages:
- English
- ISSNs:
- 1553-3506
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6328.xml