Comparison of Hill‐radial basis function, Barrett Universal and current third generation formulas for the calculation of intraocular lens power during cataract surgery. (31st August 2017)
- Record Type:
- Journal Article
- Title:
- Comparison of Hill‐radial basis function, Barrett Universal and current third generation formulas for the calculation of intraocular lens power during cataract surgery. (31st August 2017)
- Main Title:
- Comparison of Hill‐radial basis function, Barrett Universal and current third generation formulas for the calculation of intraocular lens power during cataract surgery
- Authors:
- Roberts, Timothy V
Hodge, Chris
Sutton, Gerard
Lawless, Michael - Abstract:
- Abstract: Importance: This study represents a novel comparison of recently introduced intraocular lens power calculation formulas. Background: To compare current new generation formulas for calculating the intraocular lens power for a standard cohort of patients undergoing cataract and lens replacement surgery in a private group practice in Australia. Design: Retrospective case series comparison. Participants: Postoperative results from 400 consecutive patients undergoing implantation of an SN60WF intraocular lens post cataract removal by 12 surgeons were used. Methods: Refractive outcomes were compared with expected targets to determine the predicted refractive outcomes using the Hill‐radial basis function, Barrett Universal II and readily available third or fourth generation intraocular lens power calculation formulas. Main Outcome Measure: Mean absolute predicted error. Results: The mean absolute predicted difference ranged from 0.30 to 0.34 D. There was no overall significant difference in the predicted difference or variance between formulas. All formulas achieved greater than 78.3% of eyes within ±0.5 D of intended refraction. The Hill‐radial basis function and Barrett formulas provided the lowest mean numerical error compared with existing formulas in short and long eyes, respectively. The Barrett Universal II formula had the lowest percentage of refractive surprises (>1 D from predicted error) across all axial lengths. Conclusions and Relevance: Acceptable outcomesAbstract: Importance: This study represents a novel comparison of recently introduced intraocular lens power calculation formulas. Background: To compare current new generation formulas for calculating the intraocular lens power for a standard cohort of patients undergoing cataract and lens replacement surgery in a private group practice in Australia. Design: Retrospective case series comparison. Participants: Postoperative results from 400 consecutive patients undergoing implantation of an SN60WF intraocular lens post cataract removal by 12 surgeons were used. Methods: Refractive outcomes were compared with expected targets to determine the predicted refractive outcomes using the Hill‐radial basis function, Barrett Universal II and readily available third or fourth generation intraocular lens power calculation formulas. Main Outcome Measure: Mean absolute predicted error. Results: The mean absolute predicted difference ranged from 0.30 to 0.34 D. There was no overall significant difference in the predicted difference or variance between formulas. All formulas achieved greater than 78.3% of eyes within ±0.5 D of intended refraction. The Hill‐radial basis function and Barrett formulas provided the lowest mean numerical error compared with existing formulas in short and long eyes, respectively. The Barrett Universal II formula had the lowest percentage of refractive surprises (>1 D from predicted error) across all axial lengths. Conclusions and Relevance: Acceptable outcomes can be achieved with optical biometry, consistent surgical technique and use of current intraocular lens power calculation formulas. The Barrett Universal II formula may provide the lowest risk of refractive surprise compared with other intraocular lens power calculation formulas. … (more)
- Is Part Of:
- Clinical & experimental ophthalmology. Volume 46:Number 3(2018)
- Journal:
- Clinical & experimental ophthalmology
- Issue:
- Volume 46:Number 3(2018)
- Issue Display:
- Volume 46, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 46
- Issue:
- 3
- Issue Sort Value:
- 2018-0046-0003-0000
- Page Start:
- 240
- Page End:
- 246
- Publication Date:
- 2017-08-31
- Subjects:
- cataract -- intraocular lens -- intraocular lens formula
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1442-6404&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ceo.13034 ↗
- Languages:
- English
- ISSNs:
- 1442-6404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.251920
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6315.xml