Closure of patent foramen ovale defects using GORE® CARDIOFORM septal occluder: Results from a prospective European multicenter study. Issue 5 (15th March 2017)
- Record Type:
- Journal Article
- Title:
- Closure of patent foramen ovale defects using GORE® CARDIOFORM septal occluder: Results from a prospective European multicenter study. Issue 5 (15th March 2017)
- Main Title:
- Closure of patent foramen ovale defects using GORE® CARDIOFORM septal occluder: Results from a prospective European multicenter study
- Authors:
- Hardt, Stefan E.
Eicken, Andreas
Berger, Felix
Schubert, Stephan
Carminati, Mario
Butera, Gianfranco
Grohmann, Jochen
Höhn, Rene
Nielsen‐Kudsk, Jens Erik
Hildick‐Smith, David
Settergren, Magnus
Thomson, John D.
Geis, Nicolas
Søndergaard, Lars - Abstract:
- Abstract : Aims: The GORE® CARDIOFORM Septal Occluder (GSO) is a novel device designed for rapid and effective closure of patent foramen ovale (PFO) which has distinctive features making it suitable for a broad spectrum of anatomical variations. We report the procedural and 6 months follow‐up results of the first prospective, multicenter study using GSO. Methods and Results: This single‐arm study included 150 subjects undergoing closure of PFO in 10 European centers. In 149 out of 150 patients implantation of a GSO device was successful. One patient had a different PFO‐closure device implanted. Periprocedural complications were few including one patient with suspected transient ischemic attack, two access site bleedings, and one patient with AV‐fistula. No device embolization occurred. During the 6‐month follow‐up period one patient had a transient asymptomatic thrombus on the device and four patients (2.6%) were diagnosed new onset paroxysmal atrial fibrillation, which were successfully treated. No thrombembolic events occurred. Closure was successful in 94.2% of subjects at discharge evaluation and 96.9% at 6 months follow‐up. Conclusion: This prospective, multicenter study adds to previous published data and suggests that GSO is a versatile device for PFO closure with high procedural and closure success rates and low complication rates through mid‐term follow‐up. © 2017 Wiley Periodicals, Inc.
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 90:Issue 5(2017)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 90:Issue 5(2017)
- Issue Display:
- Volume 90, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 90
- Issue:
- 5
- Issue Sort Value:
- 2017-0090-0005-0000
- Page Start:
- 824
- Page End:
- 829
- Publication Date:
- 2017-03-15
- Subjects:
- closure -- ASD/PDA/PFO -- stroke -- structural heart disease intervention
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.26993 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6313.xml