Superior cortical screw in osteoporotic lumbar vertebrae: A biomechanics and microstructure-based study. (March 2018)
- Record Type:
- Journal Article
- Title:
- Superior cortical screw in osteoporotic lumbar vertebrae: A biomechanics and microstructure-based study. (March 2018)
- Main Title:
- Superior cortical screw in osteoporotic lumbar vertebrae: A biomechanics and microstructure-based study
- Authors:
- Yu, Tianming
Zhang, Xuyang
Liu, Junhui
Li, Shengyun
Shan, Zhi
Fan, Shunwu
Zhao, Fengdong - Abstract:
- Abstract: Background: Osteoporosis reduces the bone-screw purchase, potentially reducing pullout strength and other biomechanical properties. However, the existing pedicle screw approach may not compensate for the detrimental effects of decreased vertebral bone mineral density. Methods: Two methods of screw insertion were performed in thirteen cadaveric osteoporotic lumbar vertebrae: Magerl's method in the left pedicle, and superior cortical screw method in the right (its entry point located vertically 3 mm above Magerl's point). Before screw fixations, the pedicle and its corresponding vertebral body were divided into six equal layers from cranial to caudal by performing micro-CT and tested for microstructure properties, such as bone mineral density, trabecular bone volume fraction, trabecular thickness, trabecular separation and trabecular number. Further, pedicle was horizontally divided into three regions and tested. After screw fixations, microstructure properties of the bone surrounding the screws were analyzed. Finally, the screw pullout strength was tested biomechanically. Findings: The bone structure is denser in the upper third of the pedicle and its corresponding vertebral body. A similar microstructure is seen within the pedicle. This study reveals that the pullout strength is significantly correlated to the bone mineral density, trabecular bone volume fraction and trabecular thickness. Biomechanical test showed pullout strength in the superior cortical screwAbstract: Background: Osteoporosis reduces the bone-screw purchase, potentially reducing pullout strength and other biomechanical properties. However, the existing pedicle screw approach may not compensate for the detrimental effects of decreased vertebral bone mineral density. Methods: Two methods of screw insertion were performed in thirteen cadaveric osteoporotic lumbar vertebrae: Magerl's method in the left pedicle, and superior cortical screw method in the right (its entry point located vertically 3 mm above Magerl's point). Before screw fixations, the pedicle and its corresponding vertebral body were divided into six equal layers from cranial to caudal by performing micro-CT and tested for microstructure properties, such as bone mineral density, trabecular bone volume fraction, trabecular thickness, trabecular separation and trabecular number. Further, pedicle was horizontally divided into three regions and tested. After screw fixations, microstructure properties of the bone surrounding the screws were analyzed. Finally, the screw pullout strength was tested biomechanically. Findings: The bone structure is denser in the upper third of the pedicle and its corresponding vertebral body. A similar microstructure is seen within the pedicle. This study reveals that the pullout strength is significantly correlated to the bone mineral density, trabecular bone volume fraction and trabecular thickness. Biomechanical test showed pullout strength in the superior cortical screw group with mean 613.3 N (SD 200.4) was 22.4% higher than that in the Magerl group with mean 501.2 N (SD 256.6). Interpretation: The superior cortical screw method can be a reliable alternative, to provide better pullout strength for posterior lumbar instrumentation, especially in osteoporotic patients. Highlights: Vertebral microstructure is analyzed with different layers and regions. Biomechanical strength of screw is related to vertebral microstructure. Superior cortical screw is practicable and provides better pullout strength. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 53(2018)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 53(2018)
- Issue Display:
- Volume 53, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 53
- Issue:
- 2018
- Issue Sort Value:
- 2018-0053-2018-0000
- Page Start:
- 14
- Page End:
- 21
- Publication Date:
- 2018-03
- Subjects:
- Pedicle screw -- Lumbar spine -- Micro-CT -- Pullout strength -- Osteoporosis
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2018.01.017 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6310.xml