The design and validation of a hybrid digital-signal-processing plug-in for traditional cochlear implant speech processors. (June 2018)
- Record Type:
- Journal Article
- Title:
- The design and validation of a hybrid digital-signal-processing plug-in for traditional cochlear implant speech processors. (June 2018)
- Main Title:
- The design and validation of a hybrid digital-signal-processing plug-in for traditional cochlear implant speech processors
- Authors:
- Hajiaghababa, Fatemeh
Marateb, Hamid R.
Kermani, Saeed - Abstract:
- Highlights: We introduced a new wavelet neural network (WNN) audio processing strategy for cochlear implants. The clarity of the signal was significantly improved using particle swarm optimization to tune WNN weights. The performance of the proposed method was extensively assessed using 9 criteria. The proposed algorithm showed major improvements compared with state-of-the art. Abstract: Background and objective: Cochlear implants (CIs) are electronic devices restoring partial hearing to deaf individuals with profound hearing loss. In this paper, a new plug-in for traditional IIR filter-banks (FBs) is presented for cochlear implants based on wavelet neural networks (WNNs). Having provided such a plug-in for commercially available CIs, it is possible not only to use available hardware in the market but also to optimize their performance compared with the-state-of-the-art. Methods: An online database of Dutch diphone perception was used in our study. The weights of the WNNs were tuned using particle swarm optimization (PSO) on a training set (speech-shaped noise (SSN) of 2 dB SNR), while its performance was assessed on a test set in terms of objective and composite measures in the hold-out validation framework. The cost function was defined based on the combination of mean square error (MSE), short‑time objective intelligibility (STOI) criteria on the training set. Variety of performance indices were used including segmental signal- to -noise ratio (SNRseg), MSE, STOI,Highlights: We introduced a new wavelet neural network (WNN) audio processing strategy for cochlear implants. The clarity of the signal was significantly improved using particle swarm optimization to tune WNN weights. The performance of the proposed method was extensively assessed using 9 criteria. The proposed algorithm showed major improvements compared with state-of-the art. Abstract: Background and objective: Cochlear implants (CIs) are electronic devices restoring partial hearing to deaf individuals with profound hearing loss. In this paper, a new plug-in for traditional IIR filter-banks (FBs) is presented for cochlear implants based on wavelet neural networks (WNNs). Having provided such a plug-in for commercially available CIs, it is possible not only to use available hardware in the market but also to optimize their performance compared with the-state-of-the-art. Methods: An online database of Dutch diphone perception was used in our study. The weights of the WNNs were tuned using particle swarm optimization (PSO) on a training set (speech-shaped noise (SSN) of 2 dB SNR), while its performance was assessed on a test set in terms of objective and composite measures in the hold-out validation framework. The cost function was defined based on the combination of mean square error (MSE), short‑time objective intelligibility (STOI) criteria on the training set. Variety of performance indices were used including segmental signal- to -noise ratio (SNRseg), MSE, STOI, log-likelihood ratio (LLR), weighted spectral slope (WSS), and composite measures Csig, Cbak and Covl . Meanwhile, the following CI speech processing techniques were used for comparison: traditional FBs, dual resonance nonlinear (DRNL) and simple dual path nonlinear (SPDN) models. Results: The average SNRseg, MSE, and LLR values for the WNN in the entire data set were 2.496 ± 2.794, 0.086 ± 0.025 and 2.323 ± 0.281, respectively. The proposed method significantly improved MSE, SNR, SNRseg, LLR, Csig Cbak and Covl compared with the other three methods (repeated-measures analysis of variance (ANOVA); P < 0.05). The average running time of the proposed algorithm (written in Matlab R2013a) on the training and test sets for each consonant or vowel on an Intel dual-core 2.10 GHz CPU with 2GB of RAM was 9.91 ± 0.87 (s) and 0.19 ± 0.01 (s), respectively. Conclusions: The proposed algorithm is accurate and precise and is thus a promising new plug-in for traditional CIs. Although the tuned algorithm is relatively fast, it is necessary to use efficient vectorized implementations for real-time CI speech signal processing. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 159(2018)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 159(2018)
- Issue Display:
- Volume 159, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 159
- Issue:
- 2018
- Issue Sort Value:
- 2018-0159-2018-0000
- Page Start:
- 103
- Page End:
- 109
- Publication Date:
- 2018-06
- Subjects:
- Cochlear implant -- Particle swarm optimization -- Speech processing -- Validation studies -- Wavelet neural network
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2018.03.003 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6300.xml