Effect of threshold on the correlation between airflow obstruction and low attenuation volume in smokers assessed by inspiratory and expiratory MDCT. (April 2015)
- Record Type:
- Journal Article
- Title:
- Effect of threshold on the correlation between airflow obstruction and low attenuation volume in smokers assessed by inspiratory and expiratory MDCT. (April 2015)
- Main Title:
- Effect of threshold on the correlation between airflow obstruction and low attenuation volume in smokers assessed by inspiratory and expiratory MDCT
- Authors:
- Yanagawa, Noriyuki
Kawata, Naoko
Matsuura, Yukiko
Sugiura, Toshihiko
Suzuki, Toshio
Kasai, Hajime
Irie, Ryosuke
Iesato, Ken
Tada, Yuji
Tanabe, Nobuhiro
Suzuki, Yoichi
Tatsumi, Koichiro - Abstract:
- Background: The estimation of emphysematous changes is very sensitive to computed tomography (CT) threshold level. In clinical practice, the predetermined threshold is usually set at −950 Hounsfield units (HU) for the detection of low attenuation volume (LAV). However, threshold levels that are tightly connected to pulmonary function abnormalities have not been determined. Purpose: To determine the threshold level for calculating an LAV that closely reflects airflow limitation in patients with chronic obstructive pulmonary disease (COPD). Material and Methods: Seventy-six consecutive non-COPD smokers and COPD patients underwent paired inspiratory and expiratory multidetector CT (MDCT). LAV% was segmented every 10 HU between −1000 and −750 HU to examine the correlation between LAV% and indexes of obstructive impairment. Results: LAV% gradually increased as the threshold level increased on both inspiratory and expiratory images. LAV% on inspiratory images was higher than that on expiratory images at all threshold levels between −1000 and −750 HU. The threshold level that correlated with obstructive impairment differed between the two images: −930 HU on inspiratory and −870 or −880 HU on expiratory images. Conclusion: LAV% dramatically changed according to the threshold level on both inspiratory and expiratory images, indicating that LAV% is dependent on the attenuation threshold level in patients with COPD. The threshold linking LAV% to airflow limitation was higher onBackground: The estimation of emphysematous changes is very sensitive to computed tomography (CT) threshold level. In clinical practice, the predetermined threshold is usually set at −950 Hounsfield units (HU) for the detection of low attenuation volume (LAV). However, threshold levels that are tightly connected to pulmonary function abnormalities have not been determined. Purpose: To determine the threshold level for calculating an LAV that closely reflects airflow limitation in patients with chronic obstructive pulmonary disease (COPD). Material and Methods: Seventy-six consecutive non-COPD smokers and COPD patients underwent paired inspiratory and expiratory multidetector CT (MDCT). LAV% was segmented every 10 HU between −1000 and −750 HU to examine the correlation between LAV% and indexes of obstructive impairment. Results: LAV% gradually increased as the threshold level increased on both inspiratory and expiratory images. LAV% on inspiratory images was higher than that on expiratory images at all threshold levels between −1000 and −750 HU. The threshold level that correlated with obstructive impairment differed between the two images: −930 HU on inspiratory and −870 or −880 HU on expiratory images. Conclusion: LAV% dramatically changed according to the threshold level on both inspiratory and expiratory images, indicating that LAV% is dependent on the attenuation threshold level in patients with COPD. The threshold linking LAV% to airflow limitation was higher on expiratory than on inspiratory images. … (more)
- Is Part Of:
- Acta radiologica. Volume 56:Number 4(2015:Apr.)
- Journal:
- Acta radiologica
- Issue:
- Volume 56:Number 4(2015:Apr.)
- Issue Display:
- Volume 56, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 56
- Issue:
- 4
- Issue Sort Value:
- 2015-0056-0004-0000
- Page Start:
- 438
- Page End:
- 446
- Publication Date:
- 2015-04
- Subjects:
- Chronic obstructive pulmonary disease -- multidetector computed tomography -- low attenuation volume -- threshold
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185114528489 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6288.xml