Functional outcome and health related quality of life after dual mobility cup total hip replacement for displaced femoral neck fractures in middle aged Egyptian patients. Issue 3 (March 2018)
- Record Type:
- Journal Article
- Title:
- Functional outcome and health related quality of life after dual mobility cup total hip replacement for displaced femoral neck fractures in middle aged Egyptian patients. Issue 3 (March 2018)
- Main Title:
- Functional outcome and health related quality of life after dual mobility cup total hip replacement for displaced femoral neck fractures in middle aged Egyptian patients
- Authors:
- Rashed, Ramy Ahmed
Sevenoaks, Hannah
Shabaan, Amira Mohammed
Choudry, Qaisar Akhlaq
Hammad, Abdullah Said
Kasem, Mohammed Samir
El Khadrawe, Tarek Aly
El Dakhakhny, Magdy Mohammed - Abstract:
- Abstract: Aim: This study was done to assess the functional and clinical results after one year of cemented THR with dual mobility cup for the treatment of fracture neck femur in active middle-aged patients in Egypt (Middle Eastern population). Patients and methods: This study included 31 patients (32 hips) with displaced femoral neck fractures that were admitted to El Hadara University Hospital, Alexandria, Egypt. Their mean age was 66.4 ± 5.9 years. Fifteen patients were females. All the patients were treated with total hip replacement using a cemented dual mobility cup (Ecofit ® 2 M, Implantcast GmbH, Germany) total hip replacement through the standard posterior approach. Functional assessment was done using Harris Hip Score (HHS), SF-36 questionnaire for health related quality of life (HRQoL) with assistance of a physiotherapist. Results: The mean HHS improved over the follow up period from 79.04 ± 7.9 at 12 weeks to an average of 92.8 ± 11.1 at 1 year follow up. HRQoL measures showed a pattern of initial drop at 3 months postoperatively, then a steady rise to be restored at 1 year as compared to the preoperative baseline measures. There were no dislocations encountered in this series over one year follow up. The following complications were encountered; 1 deep infection, 2 deep vein thrombosis, 2 heterotopic ossifications, and 1 patient died within one year after surgery. Conclusions: Dual mobility cup total hip replacement is an acceptable method for treatment ofAbstract: Aim: This study was done to assess the functional and clinical results after one year of cemented THR with dual mobility cup for the treatment of fracture neck femur in active middle-aged patients in Egypt (Middle Eastern population). Patients and methods: This study included 31 patients (32 hips) with displaced femoral neck fractures that were admitted to El Hadara University Hospital, Alexandria, Egypt. Their mean age was 66.4 ± 5.9 years. Fifteen patients were females. All the patients were treated with total hip replacement using a cemented dual mobility cup (Ecofit ® 2 M, Implantcast GmbH, Germany) total hip replacement through the standard posterior approach. Functional assessment was done using Harris Hip Score (HHS), SF-36 questionnaire for health related quality of life (HRQoL) with assistance of a physiotherapist. Results: The mean HHS improved over the follow up period from 79.04 ± 7.9 at 12 weeks to an average of 92.8 ± 11.1 at 1 year follow up. HRQoL measures showed a pattern of initial drop at 3 months postoperatively, then a steady rise to be restored at 1 year as compared to the preoperative baseline measures. There were no dislocations encountered in this series over one year follow up. The following complications were encountered; 1 deep infection, 2 deep vein thrombosis, 2 heterotopic ossifications, and 1 patient died within one year after surgery. Conclusions: Dual mobility cup total hip replacement is an acceptable method for treatment of displaced femoral neck fracture in active middle aged patients in Egypt as it provides pain relief and good function without compromising the stability. … (more)
- Is Part Of:
- Injury. Volume 49:Issue 3(2018)
- Journal:
- Injury
- Issue:
- Volume 49:Issue 3(2018)
- Issue Display:
- Volume 49, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 49
- Issue:
- 3
- Issue Sort Value:
- 2018-0049-0003-0000
- Page Start:
- 667
- Page End:
- 672
- Publication Date:
- 2018-03
- Subjects:
- Dual mobility cup -- Fracture neck of femur -- Total hip replacement
Wounds and injuries -- Surgery -- Periodicals
Accidents -- Periodicals
Wounds and Injuries -- surgery -- Periodicals
Lésions et blessures -- Chirurgie -- Périodiques
Electronic journals
Electronic journals
617.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00201383 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00201383 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00201383 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.injury.2018.01.006 ↗
- Languages:
- English
- ISSNs:
- 0020-1383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4514.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6272.xml