Effect of a wearable patient sensor on care delivery for preventing pressure injuries in acutely ill adults: A pragmatic randomized clinical trial (LS-HAPI study). (April 2018)
- Record Type:
- Journal Article
- Title:
- Effect of a wearable patient sensor on care delivery for preventing pressure injuries in acutely ill adults: A pragmatic randomized clinical trial (LS-HAPI study). (April 2018)
- Main Title:
- Effect of a wearable patient sensor on care delivery for preventing pressure injuries in acutely ill adults: A pragmatic randomized clinical trial (LS-HAPI study)
- Authors:
- Pickham, David
Berte, Nic
Pihulic, Mike
Valdez, Andre
Mayer, Barbara
Desai, Manisha - Abstract:
- Abstract: Importance: Though theoretically sound, studies have failed to demonstrate the benefit of routine repositioning of at-risk patients for the prevention of hospital acquired pressure injuries. Objective: To assess the clinical effectiveness of a wearable patient sensor to improve care delivery and patient outcomes by increasing the total time with turning compliance and preventing pressure injuries in acutely ill patients. Design: Pragmatic, investigator initiated, open label, single site, randomized clinical trial. Setting: Two Intensive Care Units in a large Academic Medical Center in California. Participants: Consecutive adult patients admitted to one of two Intensive Care Units between September 2015 to January 2016 were included (n = 1564). Of the eligible patients, 1312 underwent randomization. Intervention: Patients received either turning care relying on traditional turn reminders and standard practices (control group, n = 653), or optimal turning practices, influenced by real-time data derived from a wearable patient sensor (treatment group, n = 659). Main outcome(s) and Measure(s): The primary and secondary outcomes of interest were occurrence of hospital acquired pressure injury and turning compliance. Sensitivity analysis was performed to compare intention-to-treat and per-protocol effects. Results: The mean age was 60 years (SD, 17 years); 55% were male. We analyzed 103, 000 h of monitoring data. Overall the intervention group had significantly fewerAbstract: Importance: Though theoretically sound, studies have failed to demonstrate the benefit of routine repositioning of at-risk patients for the prevention of hospital acquired pressure injuries. Objective: To assess the clinical effectiveness of a wearable patient sensor to improve care delivery and patient outcomes by increasing the total time with turning compliance and preventing pressure injuries in acutely ill patients. Design: Pragmatic, investigator initiated, open label, single site, randomized clinical trial. Setting: Two Intensive Care Units in a large Academic Medical Center in California. Participants: Consecutive adult patients admitted to one of two Intensive Care Units between September 2015 to January 2016 were included (n = 1564). Of the eligible patients, 1312 underwent randomization. Intervention: Patients received either turning care relying on traditional turn reminders and standard practices (control group, n = 653), or optimal turning practices, influenced by real-time data derived from a wearable patient sensor (treatment group, n = 659). Main outcome(s) and Measure(s): The primary and secondary outcomes of interest were occurrence of hospital acquired pressure injury and turning compliance. Sensitivity analysis was performed to compare intention-to-treat and per-protocol effects. Results: The mean age was 60 years (SD, 17 years); 55% were male. We analyzed 103, 000 h of monitoring data. Overall the intervention group had significantly fewer Hospital Acquired Pressure Injuries during Intensive Care Unit admission than the control group (5 patients [0.7%] vs. 15 patients [2.3%] ( OR = 0.33, 95%CI [0.12, 0.90], p = 0.031). The total time with turning compliance was significantly different in the intervention group vs. control group (67% vs 54%; difference 0.11, 95%CI [0.08, 0.13], p < 0.001). Turning magnitude (21°, p = 0.923) and adequate depressurization time (39%, p = 0.145) were not statistically different between groups. Conclusions and Relevance: Among acutely ill adult patients requiring Intensive Care Unit admission, the provision of optimal turning was greater with a wearable patient sensor, increasing the total time with turning compliance and demonstrated a statistically significant protective effect against the development of hospital acquired pressure injuries. These are the first quantitative data on turn quality in the Intensive Care Unit and highlight the need to reinforce optimal turning practices. Additional clinical trials leveraging technologies like wearable sensors are needed to establish the appropriate frequency and dosing of individualized turning protocols to prevent pressure injuries in at-risk hospitalized patients. … (more)
- Is Part Of:
- International journal of nursing studies. Volume 80(2018)
- Journal:
- International journal of nursing studies
- Issue:
- Volume 80(2018)
- Issue Display:
- Volume 80, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 80
- Issue:
- 2018
- Issue Sort Value:
- 2018-0080-2018-0000
- Page Start:
- 12
- Page End:
- 19
- Publication Date:
- 2018-04
- Subjects:
- Bedsore -- Pressure injury -- Pressure ulcer -- Preventive turning -- Technology -- Sensor
Nursing -- Periodicals
Nursing -- Periodicals
Soins infirmiers -- Périodiques
Nursing
Periodicals
610.73 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00207489 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijnurstu.2017.12.012 ↗
- Languages:
- English
- ISSNs:
- 0020-7489
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.407000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: