The effects of flip angle optimization on the precision and reproducibility of feature tracking derived strain assessment in contrast enhanced bSSFP cine images. Issue 102 (May 2018)
- Record Type:
- Journal Article
- Title:
- The effects of flip angle optimization on the precision and reproducibility of feature tracking derived strain assessment in contrast enhanced bSSFP cine images. Issue 102 (May 2018)
- Main Title:
- The effects of flip angle optimization on the precision and reproducibility of feature tracking derived strain assessment in contrast enhanced bSSFP cine images
- Authors:
- Kuetting, Daniel L.R.
Feisst, Andreas
Dabir, Darius
Luetkens, Julian
Homsi, Rami
Thomas, Daniel
Schild, Hans H.
Sprinkart, Alois M. - Abstract:
- Abstract: Objectives: The aim of this study was to investigate whether a flip angle adaptation, which is known to improve SNR and CNR in post contrast SSFP imaging, improves the precision and reproducibility of Feature Tracking (FT) derived strain assessments in post contrast bSSFP imaging. Methods and results: At 1.5T balanced SSFP midventricular short axis cine images were acquired with various flip angles (FA) before (FA = 50°) and 5 min after (FAs = 50°, 80°, 90°, 100°) injection of double dose Gadobutrol. FT derived systolic circumferential strain was then calculated for all pre- and post-contrast images, the intra- and inter-observer variability of strain measurements was assessed. FT derived midventricular peak systolic circumferential strain (PSCS) derived from unadapted (FA: 50°) contrast enhanced bSSFP images was significantly lower than strain derived from unenhanced bSSFP images (−16.45 ± 5.1% vs −20.57 ± 6.2%; p < 0.001) and showed low agreement (mean difference of −4.13 ± 2.4, 95% CI:−5.3 to −3 ) in all 20 subjects. After adaption of the flip angle (FA: 100°), agreement between strain derived from unenhanced and adapted contrast enhanced bSSFP images (−20.57 ± 6%) was strong ( 0.01 ± 0.9, CI:−0.43 to 0.41). In comparison to intra- and interobserver variability of strain derived from unenhanced images (intra 2.9%; inter: 3.9%), strain measurements derived from adapted contrast enhanced images (FA: 100°) showed a slightly lower variability (intra: 2.5%;Abstract: Objectives: The aim of this study was to investigate whether a flip angle adaptation, which is known to improve SNR and CNR in post contrast SSFP imaging, improves the precision and reproducibility of Feature Tracking (FT) derived strain assessments in post contrast bSSFP imaging. Methods and results: At 1.5T balanced SSFP midventricular short axis cine images were acquired with various flip angles (FA) before (FA = 50°) and 5 min after (FAs = 50°, 80°, 90°, 100°) injection of double dose Gadobutrol. FT derived systolic circumferential strain was then calculated for all pre- and post-contrast images, the intra- and inter-observer variability of strain measurements was assessed. FT derived midventricular peak systolic circumferential strain (PSCS) derived from unadapted (FA: 50°) contrast enhanced bSSFP images was significantly lower than strain derived from unenhanced bSSFP images (−16.45 ± 5.1% vs −20.57 ± 6.2%; p < 0.001) and showed low agreement (mean difference of −4.13 ± 2.4, 95% CI:−5.3 to −3 ) in all 20 subjects. After adaption of the flip angle (FA: 100°), agreement between strain derived from unenhanced and adapted contrast enhanced bSSFP images (−20.57 ± 6%) was strong ( 0.01 ± 0.9, CI:−0.43 to 0.41). In comparison to intra- and interobserver variability of strain derived from unenhanced images (intra 2.9%; inter: 3.9%), strain measurements derived from adapted contrast enhanced images (FA: 100°) showed a slightly lower variability (intra: 2.5%; inter: 2.3%). Conclusion: If flip angle adaptation is performed, FT based strain analysis may be performed on contrast enhanced bSSFP cine images without loss of precision and accuracy. … (more)
- Is Part Of:
- European journal of radiology. Issue 102(2018)
- Journal:
- European journal of radiology
- Issue:
- Issue 102(2018)
- Issue Display:
- Volume 102, Issue 102 (2018)
- Year:
- 2018
- Volume:
- 102
- Issue:
- 102
- Issue Sort Value:
- 2018-0102-0102-0000
- Page Start:
- 9
- Page End:
- 14
- Publication Date:
- 2018-05
- Subjects:
- FT feature tracking -- CMR cardiac magnetic resonance -- bSSFP balanced steady-state free precession -- PSCS peak systolic circumferential strain -- FA flip angle -- TE echo time -- TR repetition time -- GFR glomerular filtration rate -- CA contrast agent -- SI signal intensities -- LVEDV left ventricular end diastolic volume -- LVEF left ventricular ejection fraction
Feature tracking -- bSSFP cine imaging -- Myocardial strain -- Gadobutrol -- Robustness
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2018.02.035 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6206.xml