Interrater reliability of the modified scapular assistance test with and without handheld weights. Issue 6 (December 2015)
- Record Type:
- Journal Article
- Title:
- Interrater reliability of the modified scapular assistance test with and without handheld weights. Issue 6 (December 2015)
- Main Title:
- Interrater reliability of the modified scapular assistance test with and without handheld weights
- Authors:
- Kopkow, Christian
Lange, Toni
Schmitt, Jochen
Kasten, Philip - Abstract:
- Abstract: Study design: Prospective, blinded interrater reliability study. Objective: To determine the interrater reliability of the modified Scapular Assistance Test (mSAT) with and without the use of additional handheld weights. Methods: 110 Shoulder patients with various shoulder pathologies were consecutively recruited. Tests were performed independently and randomly on each participant by 2 different examiners, which were blinded to further clinical information (e.g. patient history, former diagnostic results). Percent agreement, Cohen's kappa (Κ), proportion of positive/negative agreement, maximum Κ, prevalence and bias indexes and prevalence-adjusted-bias-adjusted kappa (PABAK) were calculated as estimates of interrater reliability of the mSAT with and without additional handheld weights. Weights were chosen according to body weight. Results: The reliability measures for the mSAT (Cohen's Κ: 0.68, confidence interval (CI): 0.51–0.85; PABAK: 0.78, CI: 0.67–0.90) as well as for the mSAT with handheld weights (Cohen's Κ: 0.63, CI: 0.44–0.81; PABAK: 0.76, CI: 0.64–0.88) showed substantial agreement according to the classification system proposed by Landis and Koch. Conclusions: Based on the results of this study, the mSAT with and without additional weights can be considered as reliable for clinical use. Since both tests showed substantial agreement, the use of additional handheld weights might not be necessary in case of obvious scapula dyskinesis. However, to performAbstract: Study design: Prospective, blinded interrater reliability study. Objective: To determine the interrater reliability of the modified Scapular Assistance Test (mSAT) with and without the use of additional handheld weights. Methods: 110 Shoulder patients with various shoulder pathologies were consecutively recruited. Tests were performed independently and randomly on each participant by 2 different examiners, which were blinded to further clinical information (e.g. patient history, former diagnostic results). Percent agreement, Cohen's kappa (Κ), proportion of positive/negative agreement, maximum Κ, prevalence and bias indexes and prevalence-adjusted-bias-adjusted kappa (PABAK) were calculated as estimates of interrater reliability of the mSAT with and without additional handheld weights. Weights were chosen according to body weight. Results: The reliability measures for the mSAT (Cohen's Κ: 0.68, confidence interval (CI): 0.51–0.85; PABAK: 0.78, CI: 0.67–0.90) as well as for the mSAT with handheld weights (Cohen's Κ: 0.63, CI: 0.44–0.81; PABAK: 0.76, CI: 0.64–0.88) showed substantial agreement according to the classification system proposed by Landis and Koch. Conclusions: Based on the results of this study, the mSAT with and without additional weights can be considered as reliable for clinical use. Since both tests showed substantial agreement, the use of additional handheld weights might not be necessary in case of obvious scapula dyskinesis. However, to perform the mSAT with/without additional weights should depend not only on its reliability values. Name of the public trials registry and the registration number: German Clinical Trials Register, protocol numberDRKS00005377 . Highlights: The reliability of the modified Scapular Assistance test (mSAT) was investigated. The mSAT was performed with and without additional handheld weights. Reliability measures for both testing procedures showed substantial agreement. The mSAT with and without weights can be considered as reliable for clinical use. … (more)
- Is Part Of:
- Manual therapy. Volume 20:Issue 6(2015:Dec.)
- Journal:
- Manual therapy
- Issue:
- Volume 20:Issue 6(2015:Dec.)
- Issue Display:
- Volume 20, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 20
- Issue:
- 6
- Issue Sort Value:
- 2015-0020-0006-0000
- Page Start:
- 868
- Page End:
- 874
- Publication Date:
- 2015-12
- Subjects:
- Shoulder -- Scapula -- Reproducibility of results -- Physical examination
Manipulation (Therapeutics) -- Periodicals
Physical therapy -- Periodicals
Neuromuscular diseases -- Treatment -- Periodicals
Manipulation, Orthopedic
Musculoskeletal Diseases -- therapy
Neuromuscular Diseases -- therapy
Physical Therapy
Manipulation (Thérapeutique) -- Périodiques
Physiothérapie -- Périodiques
Maladies neuromusculaires -- Traitement -- Périodiques
Manipulation (Therapeutics)
Neuromuscular diseases -- Treatment
Physical therapy
Electronic journals
Periodicals
Electronic journals
615.82 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1356-689x;screen=info;ECOIP ↗
http://www.harcourt-international.com/journals ↗
http://www.idealibrary.com/links/toc/math/ ↗
http://www.harcourt-international.com/journals/math/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/1356689X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/1356689X ↗
http://www.sciencedirect.com/science/journal/1356689X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.math.2015.04.012 ↗
- Languages:
- English
- ISSNs:
- 1356-689X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5365.380000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6194.xml