A guanidinium ionic liquid-based surfactant as an adequate solvent to separate and preconcentrate cadmium and copper in water using in situ dispersive liquid–liquid microextraction. Issue 13 (14th March 2018)
- Record Type:
- Journal Article
- Title:
- A guanidinium ionic liquid-based surfactant as an adequate solvent to separate and preconcentrate cadmium and copper in water using in situ dispersive liquid–liquid microextraction. Issue 13 (14th March 2018)
- Main Title:
- A guanidinium ionic liquid-based surfactant as an adequate solvent to separate and preconcentrate cadmium and copper in water using in situ dispersive liquid–liquid microextraction
- Authors:
- Khiat, Meriem
Pacheco-Fernández, Idaira
Pino, Verónica
Benabdallah, Tayeb
Ayala, Juan H.
Afonso, Ana M. - Abstract:
- Abstract : A guanidinium ionic liquid-based surfactant to preconcentrate cadmium and copper in water using in situ dispersive liquid–liquid microextraction. Abstract : An in situ dispersive liquid–liquid microextraction (DLLME) method together with flame atomic absorption spectroscopy (FAAS) is developed for the extraction and determination of copper and cadmium from aqueous samples using as an extraction solvent a low cytotoxic ionic liquid (IL)-based surfactant, specifically decylguanidinium chloride (C10 Gu-Cl). The IL-based surfactant 1-hexadecyl-3-butylimidazolium bromide (C16 C4 Im-Br) is also used for comparative purposes. In the method, N, N ′-bis(salicylidene)thiocarbohydrazide is the complexing agent, and the metathesis reaction in the in situ DLLME is accomplished using lithium bis[(trifluoromethyl)sulfonyl]imide. The main parameters affecting the extraction efficiency of the method, i.e. pH of the sample, NaCl content, and vortex time, are properly optimized with a Doehlert experimental design. The method using C10 Gu-Cl exhibited a limit of detection (LOD) four times lower and with slightly better reproducibility than that of the imidazolium IL-based surfactant. The validation of the in situ DLLME-FAAS method with C10 Gu-Cl is accomplished for the simultaneous extraction and quantification of copper and cadmium from water. The optimum method requires 10 mL of aqueous sample and ∼25 μL of the IL-based surfactant to obtain a microdroplet of ∼21 μL, which isAbstract : A guanidinium ionic liquid-based surfactant to preconcentrate cadmium and copper in water using in situ dispersive liquid–liquid microextraction. Abstract : An in situ dispersive liquid–liquid microextraction (DLLME) method together with flame atomic absorption spectroscopy (FAAS) is developed for the extraction and determination of copper and cadmium from aqueous samples using as an extraction solvent a low cytotoxic ionic liquid (IL)-based surfactant, specifically decylguanidinium chloride (C10 Gu-Cl). The IL-based surfactant 1-hexadecyl-3-butylimidazolium bromide (C16 C4 Im-Br) is also used for comparative purposes. In the method, N, N ′-bis(salicylidene)thiocarbohydrazide is the complexing agent, and the metathesis reaction in the in situ DLLME is accomplished using lithium bis[(trifluoromethyl)sulfonyl]imide. The main parameters affecting the extraction efficiency of the method, i.e. pH of the sample, NaCl content, and vortex time, are properly optimized with a Doehlert experimental design. The method using C10 Gu-Cl exhibited a limit of detection (LOD) four times lower and with slightly better reproducibility than that of the imidazolium IL-based surfactant. The validation of the in situ DLLME-FAAS method with C10 Gu-Cl is accomplished for the simultaneous extraction and quantification of copper and cadmium from water. The optimum method requires 10 mL of aqueous sample and ∼25 μL of the IL-based surfactant to obtain a microdroplet of ∼21 μL, which is diluted up to 120 μL with acetonitrile to perform the analytical determination of both metals. LODs down to 0.3 and 0.5 μg L −1 were reached with the entire in situ IL-DLLME-FAAS for copper and cadmium, respectively. The inter-day relative standard deviation values were lower than 17% for both metal ions; with relative recoveries of 97.8% and 102%, and enrichment factors of 85 and 94, for copper and cadmium, respectively, at a low spiked level (4 and 6 μg L −1, respectively). Furthermore, the developed method shows adequate precision and accuracy evaluated with a certified reference material, the absence of matrix effects, and high tolerance limits towards common cations (between 80 and 600) for the analysis of tap water, while accomplishing the requirements of green analytical chemistry. … (more)
- Is Part Of:
- Analytical methods. Volume 10:Issue 13(2018)
- Journal:
- Analytical methods
- Issue:
- Volume 10:Issue 13(2018)
- Issue Display:
- Volume 10, Issue 13 (2018)
- Year:
- 2018
- Volume:
- 10
- Issue:
- 13
- Issue Sort Value:
- 2018-0010-0013-0000
- Page Start:
- 1529
- Page End:
- 1537
- Publication Date:
- 2018-03-14
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c8ay00022k ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6178.xml