Patient‐specific calibration of cone‐beam computed tomography data sets for radiotherapy dose calculations and treatment plan assessment. (26th February 2018)
- Record Type:
- Journal Article
- Title:
- Patient‐specific calibration of cone‐beam computed tomography data sets for radiotherapy dose calculations and treatment plan assessment. (26th February 2018)
- Main Title:
- Patient‐specific calibration of cone‐beam computed tomography data sets for radiotherapy dose calculations and treatment plan assessment
- Authors:
- MacFarlane, Michael
Wong, Daniel
Hoover, Douglas A.
Wong, Eugene
Johnson, Carol
Battista, Jerry J.
Chen, Jeff Z. - Abstract:
- Abstract: Purpose: In this work, we propose a new method of calibrating cone beam computed tomography (CBCT) data sets for radiotherapy dose calculation and plan assessment. The motivation for this patient‐specific calibration (PSC) method is to develop an efficient, robust, and accurate CBCT calibration process that is less susceptible to deformable image registration (DIR) errors. Methods: Instead of mapping the CT numbers voxel‐by‐voxel with traditional DIR calibration methods, the PSC methods generates correlation plots between deformably registered planning CT and CBCT voxel values, for each image slice . A linear calibration curve specific to each slice is then obtained by least‐squares fitting, and applied to the CBCT slice's voxel values. This allows each CBCT slice to be corrected using DIR without altering the patient geometry through regional DIR errors. A retrospective study was performed on 15 head‐and‐neck cancer patients, each having routine CBCTs and a middle‐of‐treatment re‐planning CT (reCT). The original treatment plan was re‐calculated on the patient's reCT image set (serving as the gold standard) as well as the image sets produced by voxel‐to‐voxel DIR, density‐overriding, and the new PSC calibration methods. Dose accuracy of each calibration method was compared to the reference reCT data set using common dose‐volume metrics and 3D gamma analysis. A phantom study was also performed to assess the accuracy of the DIR and PSC CBCT calibration methodsAbstract: Purpose: In this work, we propose a new method of calibrating cone beam computed tomography (CBCT) data sets for radiotherapy dose calculation and plan assessment. The motivation for this patient‐specific calibration (PSC) method is to develop an efficient, robust, and accurate CBCT calibration process that is less susceptible to deformable image registration (DIR) errors. Methods: Instead of mapping the CT numbers voxel‐by‐voxel with traditional DIR calibration methods, the PSC methods generates correlation plots between deformably registered planning CT and CBCT voxel values, for each image slice . A linear calibration curve specific to each slice is then obtained by least‐squares fitting, and applied to the CBCT slice's voxel values. This allows each CBCT slice to be corrected using DIR without altering the patient geometry through regional DIR errors. A retrospective study was performed on 15 head‐and‐neck cancer patients, each having routine CBCTs and a middle‐of‐treatment re‐planning CT (reCT). The original treatment plan was re‐calculated on the patient's reCT image set (serving as the gold standard) as well as the image sets produced by voxel‐to‐voxel DIR, density‐overriding, and the new PSC calibration methods. Dose accuracy of each calibration method was compared to the reference reCT data set using common dose‐volume metrics and 3D gamma analysis. A phantom study was also performed to assess the accuracy of the DIR and PSC CBCT calibration methods compared with planning CT. Results: Compared with the gold standard using reCT, the average dose metric differences were ≤ 1.1% for all three methods (PSC: −0.3%; DIR: −0.7%; density‐override: −1.1%). The average gamma pass rates with thresholds 3%, 3 mm were also similar among the three techniques (PSC: 95.0%; DIR: 96.1%; density‐override: 94.4%). Conclusions: An automated patient‐specific calibration method was developed which yielded strong dosimetric agreement with the results obtained using a re‐planning CT for head‐and‐neck patients. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 19:Number 2(2018)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 19:Number 2(2018)
- Issue Display:
- Volume 19, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 19
- Issue:
- 2
- Issue Sort Value:
- 2018-0019-0002-0000
- Page Start:
- 249
- Page End:
- 257
- Publication Date:
- 2018-02-26
- Subjects:
- CBCT -- DIR -- dose tracking -- treatment plan assessment
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12293 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6177.xml