Establishing upper limits on neuronal activity–evoked pH changes with APT‐CEST MRI at 7 T. Issue 1 (20th November 2017)
- Record Type:
- Journal Article
- Title:
- Establishing upper limits on neuronal activity–evoked pH changes with APT‐CEST MRI at 7 T. Issue 1 (20th November 2017)
- Main Title:
- Establishing upper limits on neuronal activity–evoked pH changes with APT‐CEST MRI at 7 T
- Authors:
- Khlebnikov, Vitaliy
Siero, Jeroen C.W.
Bhogal, Alex A.
Luijten, Peter R.
Klomp, Dennis W.J.
Hoogduin, Hans - Abstract:
- Abstract : Purpose: To detect neuronal activity–evoked pH changes by amide proton transfer–chemical exchange saturation transfer (APT‐CEST) MRI at 7 T. Methods: Three healthy subjects participated in the study. A low‐power 3‐dimensional APT‐CEST sequence was optimized through the Bloch‐McConnell equations. pH sensitivity of the sequence was estimated both in phantoms and in vivo. The feasibility of pH–functional MRI was tested in Bloch‐McConnell‐simulated data using the optimized sequence. In healthy subjects, the visual stimuli were used to evoke transient pH changes in the visual cortex, and a 3‐dimensional APT‐CEST volume was acquired at the pH‐sensitive frequency offset of 3.5 ppm every 12.6 s. Results: In theory, a three‐component general linear model was capable of separating the effects of blood oxygenation level–dependent contrast and pH. The Bloch‐McConnell equations indicated that a change in pH of 0.03 should be measurable at the experimentally determined temporal signal‐to‐noise ratio of 108. However, only a blood oxygenation level–dependent effect in the visual cortex could be discerned during the visual stimuli experiments performed in the healthy subjects. Conclusions: The results of this study suggest that if indeed there are any transient brain pH changes in response to visual stimuli, those are under 0.03 units pH change, which is extremely difficult to detect using the existent techniques. Magn Reson Med 80:126–136, 2018. © 2017 The Authors MagneticAbstract : Purpose: To detect neuronal activity–evoked pH changes by amide proton transfer–chemical exchange saturation transfer (APT‐CEST) MRI at 7 T. Methods: Three healthy subjects participated in the study. A low‐power 3‐dimensional APT‐CEST sequence was optimized through the Bloch‐McConnell equations. pH sensitivity of the sequence was estimated both in phantoms and in vivo. The feasibility of pH–functional MRI was tested in Bloch‐McConnell‐simulated data using the optimized sequence. In healthy subjects, the visual stimuli were used to evoke transient pH changes in the visual cortex, and a 3‐dimensional APT‐CEST volume was acquired at the pH‐sensitive frequency offset of 3.5 ppm every 12.6 s. Results: In theory, a three‐component general linear model was capable of separating the effects of blood oxygenation level–dependent contrast and pH. The Bloch‐McConnell equations indicated that a change in pH of 0.03 should be measurable at the experimentally determined temporal signal‐to‐noise ratio of 108. However, only a blood oxygenation level–dependent effect in the visual cortex could be discerned during the visual stimuli experiments performed in the healthy subjects. Conclusions: The results of this study suggest that if indeed there are any transient brain pH changes in response to visual stimuli, those are under 0.03 units pH change, which is extremely difficult to detect using the existent techniques. Magn Reson Med 80:126–136, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 80:Issue 1(2018)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 80:Issue 1(2018)
- Issue Display:
- Volume 80, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 80
- Issue:
- 1
- Issue Sort Value:
- 2018-0080-0001-0000
- Page Start:
- 126
- Page End:
- 136
- Publication Date:
- 2017-11-20
- Subjects:
- CEST -- APT‐CEST -- pH‐fMRI -- hypercapnia -- Bloch‐McConnell equations
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27013 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6172.xml