A smartphone-based double-channel fluorescence setup for immunoassay of a carcinoembryonic antigen using CuS nanoparticles for signal amplification. Issue 7 (7th March 2018)
- Record Type:
- Journal Article
- Title:
- A smartphone-based double-channel fluorescence setup for immunoassay of a carcinoembryonic antigen using CuS nanoparticles for signal amplification. Issue 7 (7th March 2018)
- Main Title:
- A smartphone-based double-channel fluorescence setup for immunoassay of a carcinoembryonic antigen using CuS nanoparticles for signal amplification
- Authors:
- Wang, Honghai
Sun, Yan
Yue, Weiwei
Kang, Qi
Li, Huijuan
Shen, Dazhong - Abstract:
- Abstract : Sensitive detection of cancer biomarkers is valuable for clinical diagnosis and treatment assessment of cancers. Abstract : Sensitive detection of cancer biomarkers is valuable for clinical diagnosis and treatment assessment of cancers. Herein, we report a simple smartphone-based double-channel fluorescence setup for immunoassay. Not including the smartphone, the total cost of the detection device itself is about 80 $, including a laser pointer, a twinning measurement cell, a collective lens, and an outside box. The fluorescence images of the sample and reference areas were captured by the camera in the smartphone and the brightness ratio was calculated using a user-edited smartphone app. By using 2, 3-diaminophenazine (DAP) as the model luminophore, the influence of exposure time and photosensitivity on the sensitivity was tested. The brightness ratio offers high stability of the fluorescence signal, which is helpful to improve the sensitivity. The applicability of this device was demonstrated by a catalytic fluorimetric method for Cu 2+ determination, which is based on the oxidation of o -phenylenediamine (non-fluorescent) to DAP (strong fluorescent) by dissolved oxygen using Cu 2+ as the catalyst. Accordingly, by using a CuS nanoparticle-conjugated second antibody as the signal tag, the immunoassay for a carcinoembryonic antigen was performed with the detection limit of 0.05 pg mL −1 . This smartphone-based double-channel fluorescence device offers theAbstract : Sensitive detection of cancer biomarkers is valuable for clinical diagnosis and treatment assessment of cancers. Abstract : Sensitive detection of cancer biomarkers is valuable for clinical diagnosis and treatment assessment of cancers. Herein, we report a simple smartphone-based double-channel fluorescence setup for immunoassay. Not including the smartphone, the total cost of the detection device itself is about 80 $, including a laser pointer, a twinning measurement cell, a collective lens, and an outside box. The fluorescence images of the sample and reference areas were captured by the camera in the smartphone and the brightness ratio was calculated using a user-edited smartphone app. By using 2, 3-diaminophenazine (DAP) as the model luminophore, the influence of exposure time and photosensitivity on the sensitivity was tested. The brightness ratio offers high stability of the fluorescence signal, which is helpful to improve the sensitivity. The applicability of this device was demonstrated by a catalytic fluorimetric method for Cu 2+ determination, which is based on the oxidation of o -phenylenediamine (non-fluorescent) to DAP (strong fluorescent) by dissolved oxygen using Cu 2+ as the catalyst. Accordingly, by using a CuS nanoparticle-conjugated second antibody as the signal tag, the immunoassay for a carcinoembryonic antigen was performed with the detection limit of 0.05 pg mL −1 . This smartphone-based double-channel fluorescence device offers the advantages of high sensitivity, inexpensive and miniaturization. … (more)
- Is Part Of:
- Analyst. Volume 143:Issue 7(2018)
- Journal:
- Analyst
- Issue:
- Volume 143:Issue 7(2018)
- Issue Display:
- Volume 143, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 143
- Issue:
- 7
- Issue Sort Value:
- 2018-0143-0007-0000
- Page Start:
- 1670
- Page End:
- 1678
- Publication Date:
- 2018-03-07
- Subjects:
- Chemistry, Analytic -- Periodicals
543 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/an?e=1#!issueid=an139020&type=current&issnprint=0003-2654 ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c7an01988b ↗
- Languages:
- English
- ISSNs:
- 0003-2654
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0893.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6155.xml