Acute toxicity of the bowel after stereotactic robotic radiotherapy for abdominopelvic oligometastases. (3rd April 2018)
- Record Type:
- Journal Article
- Title:
- Acute toxicity of the bowel after stereotactic robotic radiotherapy for abdominopelvic oligometastases. (3rd April 2018)
- Main Title:
- Acute toxicity of the bowel after stereotactic robotic radiotherapy for abdominopelvic oligometastases
- Authors:
- Frelinghuysen, Michael
Schillemans, Wilco
Hol, Lieke
Verhoef, Cornelis
Hoogeman, Mischa
Nuyttens, Joost Jan - Abstract:
- Abstract: Aim: To correlate dose-volume histogram (DVH) parameters with appearance of grade ≥2 acute and late gastrointestinal toxicity of stereotactic body radiotherapy (SBRT) in patients with abdominopelvic solitary or oligometastatic disease outside the liver. Material and methods: Acute and late bowel toxicity of 84 abdominopelvic oligometastatic patients was registered. A logistic regression was performed between different DVH parameters and presence of grade ≥2 acute and late toxicity. A Normal Tissue Complication Probability (NTCP) model was built with significant parameters to determine complication probabilities (CP). Results: Thirteen (15%) of 84 patients experienced of grade ≥2 acute toxicity, while 8 (10%) reported late toxicity complications. A significant relationship was found for EQD2 (V30Gy, V40Gy, V50Gy and V65Gy ) and grade ≥2 acute toxicity. Dmax and D2 were not significant. Late grade ≥2 toxicity was not significantly correlated with any DVH parameter. According to our NTCP model for V40Gy, an irradiated bowel volume of 10 cm 3 of V40Gy resulted in CP of grade ≥2 acute toxicity of less than 10%. Local control was 87% at 2 years and 82% at 5 years. Overall survival was 61% at 2 years and 32% at 5 years. Conclusions: After SBRT for abdominopelvic oligometastases, in general, the presence of acute and late toxicity was low. A significant relationship was found for V30Gy, V40Gy, V50Gy and V65Gy and grade ≥2 acute toxicity. We estimated acute complicationAbstract: Aim: To correlate dose-volume histogram (DVH) parameters with appearance of grade ≥2 acute and late gastrointestinal toxicity of stereotactic body radiotherapy (SBRT) in patients with abdominopelvic solitary or oligometastatic disease outside the liver. Material and methods: Acute and late bowel toxicity of 84 abdominopelvic oligometastatic patients was registered. A logistic regression was performed between different DVH parameters and presence of grade ≥2 acute and late toxicity. A Normal Tissue Complication Probability (NTCP) model was built with significant parameters to determine complication probabilities (CP). Results: Thirteen (15%) of 84 patients experienced of grade ≥2 acute toxicity, while 8 (10%) reported late toxicity complications. A significant relationship was found for EQD2 (V30Gy, V40Gy, V50Gy and V65Gy ) and grade ≥2 acute toxicity. Dmax and D2 were not significant. Late grade ≥2 toxicity was not significantly correlated with any DVH parameter. According to our NTCP model for V40Gy, an irradiated bowel volume of 10 cm 3 of V40Gy resulted in CP of grade ≥2 acute toxicity of less than 10%. Local control was 87% at 2 years and 82% at 5 years. Overall survival was 61% at 2 years and 32% at 5 years. Conclusions: After SBRT for abdominopelvic oligometastases, in general, the presence of acute and late toxicity was low. A significant relationship was found for V30Gy, V40Gy, V50Gy and V65Gy and grade ≥2 acute toxicity. We estimated acute complication probabilities per volume of irradiated bowel by V40Gy and V50Gy … (more)
- Is Part Of:
- Acta oncologica. Volume 57:Number 4(2018)
- Journal:
- Acta oncologica
- Issue:
- Volume 57:Number 4(2018)
- Issue Display:
- Volume 57, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 57
- Issue:
- 4
- Issue Sort Value:
- 2018-0057-0004-0000
- Page Start:
- 480
- Page End:
- 484
- Publication Date:
- 2018-04-03
- Subjects:
- Oncology -- Periodicals
Cancer -- Treatment -- Periodicals
616.992 - Journal URLs:
- http://informahealthcare.com/loi/onc ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/0284186X.2017.1378432 ↗
- Languages:
- English
- ISSNs:
- 0284-186X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.705000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6146.xml