Flow artifact in the anterior communicating artery resembling aneurysm on the time of flight MR angiogram. (December 2014)
- Record Type:
- Journal Article
- Title:
- Flow artifact in the anterior communicating artery resembling aneurysm on the time of flight MR angiogram. (December 2014)
- Main Title:
- Flow artifact in the anterior communicating artery resembling aneurysm on the time of flight MR angiogram
- Authors:
- Takhtani, Deepak
Dundamadappa, Sathish
Puri, Ajit S
Wakhloo, Ajay - Abstract:
- Background: Magnetic resonance angiogram (MRA) of the brain is a widely employed non-invasive test to diagnose aneurysms. However, its overall accuracy is less than digital subtraction angiography and is prone to give false-positive or false-negative results. False-negative results can be seen with hemorrhage, lipoma, dermoid, posterior lobe of the pituitary gland, and the flow artifacts. Purpose: To describe the findings associated with false aneurysms in the anterior communicating artery on the time of flight MRA and review the physical principles behind this artifact. Material and Methods: This short series comprises of four patients whose MRA showed suspicious aneurysms in the region of the anterior communicating artery (ACOM) on time of flight MRA. Results: Two patients underwent catheter angiogram and the other two patients had computed tomography angiogram. None of these cases proved to have aneurysms and normal anterior communicating arteries were seen in all the patients. The findings on the MR angiograms were considered artifacts. All of the pseudoaneurysm had tapered appearance. Conclusion: MR angiogram can result in artifacts at ACOM which may be mistaken for aneurysm. Such pseudoaneurysms have characteristic appearance and should be followed up with non-invasive tests.
- Is Part Of:
- Acta radiologica. Volume 55:Number 10(2014:Dec.)
- Journal:
- Acta radiologica
- Issue:
- Volume 55:Number 10(2014:Dec.)
- Issue Display:
- Volume 55, Issue 10 (2014)
- Year:
- 2014
- Volume:
- 55
- Issue:
- 10
- Issue Sort Value:
- 2014-0055-0010-0000
- Page Start:
- 1253
- Page End:
- 1257
- Publication Date:
- 2014-12
- Subjects:
- Magnetic resonance angiography (MRA) -- artifact -- anterior communicating artery (ACOM) -- turbulent flow -- pseudoaneurysm
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185113520153 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6114.xml