Contrast material and radiation dose reduction strategy for triple-rule-out cardiac CT angiography: feasibility study of non-ECG-gated low kVp scan of the whole chest following coronary CT angiography. (December 2014)
- Record Type:
- Journal Article
- Title:
- Contrast material and radiation dose reduction strategy for triple-rule-out cardiac CT angiography: feasibility study of non-ECG-gated low kVp scan of the whole chest following coronary CT angiography. (December 2014)
- Main Title:
- Contrast material and radiation dose reduction strategy for triple-rule-out cardiac CT angiography: feasibility study of non-ECG-gated low kVp scan of the whole chest following coronary CT angiography
- Authors:
- Kidoh, Masafumi
Nakaura, Takeshi
Nakamura, Shinichi
Namimoto, Tomohiro
Nozaki, Toshimitsu
Sakaino, Naritsugu
Harada, Kazunori
Yamashita, Yasuyuki - Abstract:
- Background: Dedicated coronary computed tomography (CT) scan has been proven to be an accurate diagnostic modality in evaluating coronary artery disease. A second phase scan starting immediately after the coronary CT scan might enable visualization of the different vascular territories of the entire chest. Purpose: To investigate the feasibility of a contrast material and radiation dose reduction triple-rule-out (TRO) CT angiography (CTA) protocol with serial non-ECG-gated low kVp scan of the whole chest, which utilizes a recirculated contrast agent. Material and Methods: Thirty patients were scanned with the new TRO-CTA protocol; after the coronary scan with retrospective ECG-gating, non-ECG-gated whole-chest CTA was performed at 80 kVp to evaluate aortic arch (AAr) and pulmonary trunk (PT). Another 30 patients were scanned by our conventional TRO-CTA protocol at 120 kVp with retrospective ECG-gating. We compared the estimated effective dose (ED), contrast material (CM) dose, contrast-to-noise ratio (CNR) of the ascending aorta (AAo), and the rate of patients who could achieve adequate attenuation of the AAr and PT between the two protocols. Results: The total ED of the new TRO-CTA protocol was 29.6% lower than that of the conventional protocol ( P < 0.01). The amount of CM used for the new TRO-CTA protocol was significantly lower than in the conventional protocol (60.1 ± 9.6 mL vs . 91.8 ± 22.6 mL, P < 0.01). The CNR of the AAo was 30.2% higher with the new TRO-CTABackground: Dedicated coronary computed tomography (CT) scan has been proven to be an accurate diagnostic modality in evaluating coronary artery disease. A second phase scan starting immediately after the coronary CT scan might enable visualization of the different vascular territories of the entire chest. Purpose: To investigate the feasibility of a contrast material and radiation dose reduction triple-rule-out (TRO) CT angiography (CTA) protocol with serial non-ECG-gated low kVp scan of the whole chest, which utilizes a recirculated contrast agent. Material and Methods: Thirty patients were scanned with the new TRO-CTA protocol; after the coronary scan with retrospective ECG-gating, non-ECG-gated whole-chest CTA was performed at 80 kVp to evaluate aortic arch (AAr) and pulmonary trunk (PT). Another 30 patients were scanned by our conventional TRO-CTA protocol at 120 kVp with retrospective ECG-gating. We compared the estimated effective dose (ED), contrast material (CM) dose, contrast-to-noise ratio (CNR) of the ascending aorta (AAo), and the rate of patients who could achieve adequate attenuation of the AAr and PT between the two protocols. Results: The total ED of the new TRO-CTA protocol was 29.6% lower than that of the conventional protocol ( P < 0.01). The amount of CM used for the new TRO-CTA protocol was significantly lower than in the conventional protocol (60.1 ± 9.6 mL vs . 91.8 ± 22.6 mL, P < 0.01). The CNR of the AAo was 30.2% higher with the new TRO-CTA protocol than with the conventional protocol ( P < 0.01). There was no significant difference in the success rate of adequate attenuation of the AAr and PT between the two protocols ( P > 0.05). Conclusion: The new TRO-CTA protocol can reduce the total dose of radiation and the contrast dose and yield adequate vascular enhancement compared with the conventional protocol. … (more)
- Is Part Of:
- Acta radiologica. Volume 55:Number 10(2014:Dec.)
- Journal:
- Acta radiologica
- Issue:
- Volume 55:Number 10(2014:Dec.)
- Issue Display:
- Volume 55, Issue 10 (2014)
- Year:
- 2014
- Volume:
- 55
- Issue:
- 10
- Issue Sort Value:
- 2014-0055-0010-0000
- Page Start:
- 1186
- Page End:
- 1196
- Publication Date:
- 2014-12
- Subjects:
- Triple-rule-out CT angiography -- low tube voltage -- radiation dose -- contrast dose
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185113514886 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6114.xml