Laser Balloon or Wide-Area Circumferential Irrigated Radiofrequency Ablation for Persistent Atrial Fibrillation: A Multicenter Prospective Randomized Study. (December 2017)
- Record Type:
- Journal Article
- Title:
- Laser Balloon or Wide-Area Circumferential Irrigated Radiofrequency Ablation for Persistent Atrial Fibrillation: A Multicenter Prospective Randomized Study. (December 2017)
- Main Title:
- Laser Balloon or Wide-Area Circumferential Irrigated Radiofrequency Ablation for Persistent Atrial Fibrillation
- Authors:
- Schmidt, Boris
Neuzil, Petr
Luik, Armin
Osca Asensi, Joaquin
Schrickel, Jan Wilko
Deneke, Thomas
Bordignon, Stefano
Petru, Jan
Merkel, Matthias
Sediva, Lucie
Klostermann, Annemarie
Perrotta, Laura
Cano, Oscar
Chun, K.R. Julian - Abstract:
- Abstract : Background: Pulmonary vein isolation is the cornerstone of ablation for persistent atrial fibrillation (AF). The role of balloon catheters in this patient population remains ill defined. We sought to compare efficacy and safety of the laser balloon (LB) with wide-area circumferential pulmonary vein isolation using irrigated radiofrequency current (RF) ablation and 3-dimensional mapping. Methods and Results: In 6 European centers, patients with persistent AF were prospectively randomized. Follow-up included 3-day Holter ECG recordings and office visits at 3, 6, and 12 months. The primary efficacy end point was freedom from AF between 90 and 365 days after a single ablation. The primary safety end point was the incidence of any periprocedural complications. Of 152 enrolled patients, 134 (n=68 LB and 66 RF; 63% men; mean age, 66+10 years) with persistent AF (median AF history, 14 months; Q1–Q3, 7–36 months) underwent pulmonary vein isolation and completed the entire follow-up. Baseline parameters were similar in both groups. Procedure and fluoroscopy times were similar in both groups (135±38 and 14±9 minutes (LB) versus 128±51 and 11±9 minutes). The primary efficacy end point was met by 71.2% versus 69.3%, in the LB and RF groups, respectively ( P =0.40). In the LB group, stroke (n=1), a false aneurysm (n=1), and phrenic nerve palsy (n=1) were observed. In the RF group, 2 patients developed a false aneurysm, and 1 patient needed surgical repair. Conclusions: AnAbstract : Background: Pulmonary vein isolation is the cornerstone of ablation for persistent atrial fibrillation (AF). The role of balloon catheters in this patient population remains ill defined. We sought to compare efficacy and safety of the laser balloon (LB) with wide-area circumferential pulmonary vein isolation using irrigated radiofrequency current (RF) ablation and 3-dimensional mapping. Methods and Results: In 6 European centers, patients with persistent AF were prospectively randomized. Follow-up included 3-day Holter ECG recordings and office visits at 3, 6, and 12 months. The primary efficacy end point was freedom from AF between 90 and 365 days after a single ablation. The primary safety end point was the incidence of any periprocedural complications. Of 152 enrolled patients, 134 (n=68 LB and 66 RF; 63% men; mean age, 66+10 years) with persistent AF (median AF history, 14 months; Q1–Q3, 7–36 months) underwent pulmonary vein isolation and completed the entire follow-up. Baseline parameters were similar in both groups. Procedure and fluoroscopy times were similar in both groups (135±38 and 14±9 minutes (LB) versus 128±51 and 11±9 minutes). The primary efficacy end point was met by 71.2% versus 69.3%, in the LB and RF groups, respectively ( P =0.40). In the LB group, stroke (n=1), a false aneurysm (n=1), and phrenic nerve palsy (n=1) were observed. In the RF group, 2 patients developed a false aneurysm, and 1 patient needed surgical repair. Conclusions: An LB-guided strategy was associated with similar efficacy as wide-area circumferential pulmonary vein isolation using irrigated RF in patients with persistent AF. Clinical Trial Registration: https://www.clinicaltrials.org . Unique identifier: NCT01863472. … (more)
- Is Part Of:
- Circulation. Volume 10:Number 12(2017)
- Journal:
- Circulation
- Issue:
- Volume 10:Number 12(2017)
- Issue Display:
- Volume 10, Issue 12 (2017)
- Year:
- 2017
- Volume:
- 10
- Issue:
- 12
- Issue Sort Value:
- 2017-0010-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-12
- Subjects:
- atrial fibrillation -- follow-up studies -- lasers -- office visits -- pulmonary veins
Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.117.005767 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6064.xml