A Histological Comparison of Two Human Acellular Dermal Matrix Products in Prosthetic-Based Breast Reconstruction. Issue 12 (December 2017)
- Record Type:
- Journal Article
- Title:
- A Histological Comparison of Two Human Acellular Dermal Matrix Products in Prosthetic-Based Breast Reconstruction. Issue 12 (December 2017)
- Main Title:
- A Histological Comparison of Two Human Acellular Dermal Matrix Products in Prosthetic-Based Breast Reconstruction
- Authors:
- Moyer, Hunter R.
Hart, Alexandra M.
Yeager, Jessica
Losken, Albert - Abstract:
- Abstract : Background: Acellular dermal matrices (ADMs) are an integral component of breast reconstruction. The ideal matrix would be relatively immuno-inert, allow rapid vascularization, and be affordable. The purpose of this study was to histologically compare 2 commonly used ADM products. Methods: This is a prospective histological study of 17 patients (20 breasts) following prosthetic-based breast reconstruction with ADM: Alloderm (LifeCell Corp, Branchburg, N.J.) or Cortiva (RTI Surgical, Alachua Fla.). Biopsies were taken from the dermal matrix and natural capsules surrounding the expander/implant during secondary surgery [Range, 72—694 days (mean, 217 days)]. Biopsy specimens were prepared via hematoxylin and eosin, Masson's trichrome, elastin, and transforming growth factor (TGF)-1 stains. Quantitative analysis of staining was performed with ImageJ software. The clinical outcome of each patient is analyzed in relation to capsule architecture and ADM performance. Results: There were 7 breasts in the Alloderm group and 13 in the Cortiva group. Both groups had similar demographic, aesthetic results, and complication profiles. The TGF-1 staining demonstrated significantly lower levels in the Cortiva capsules ( P = 0.0139). The percentage of elastin and collagen are similar in the Cortiva, Alloderm, and natural peri-implant capsules. The native capsules show a significantly greater number of blood vessels when compared with Cortiva and Alloderm ( P = 0.0371 and P =Abstract : Background: Acellular dermal matrices (ADMs) are an integral component of breast reconstruction. The ideal matrix would be relatively immuno-inert, allow rapid vascularization, and be affordable. The purpose of this study was to histologically compare 2 commonly used ADM products. Methods: This is a prospective histological study of 17 patients (20 breasts) following prosthetic-based breast reconstruction with ADM: Alloderm (LifeCell Corp, Branchburg, N.J.) or Cortiva (RTI Surgical, Alachua Fla.). Biopsies were taken from the dermal matrix and natural capsules surrounding the expander/implant during secondary surgery [Range, 72—694 days (mean, 217 days)]. Biopsy specimens were prepared via hematoxylin and eosin, Masson's trichrome, elastin, and transforming growth factor (TGF)-1 stains. Quantitative analysis of staining was performed with ImageJ software. The clinical outcome of each patient is analyzed in relation to capsule architecture and ADM performance. Results: There were 7 breasts in the Alloderm group and 13 in the Cortiva group. Both groups had similar demographic, aesthetic results, and complication profiles. The TGF-1 staining demonstrated significantly lower levels in the Cortiva capsules ( P = 0.0139). The percentage of elastin and collagen are similar in the Cortiva, Alloderm, and natural peri-implant capsules. The native capsules show a significantly greater number of blood vessels when compared with Cortiva and Alloderm ( P = 0.0371 and P = 0.0347, respectively); however, there is no difference in vascular pattern between the 2 dermal matrices. Discussion: Postoperatively, Cortiva demonstrates equal vascularity with less TGF-1 activation compared with Alloderm. The clinical success and complication profile were similar between the Alloderm and Cortiva patients. … (more)
- Is Part Of:
- Plastic and reconstructive surgery. Volume 5:Issue 12(2017)
- Journal:
- Plastic and reconstructive surgery
- Issue:
- Volume 5:Issue 12(2017)
- Issue Display:
- Volume 5, Issue 12 (2017)
- Year:
- 2017
- Volume:
- 5
- Issue:
- 12
- Issue Sort Value:
- 2017-0005-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-12
- Subjects:
- Surgery, Plastic -- Periodicals
Surgery, Plastic -- Periodicals
Reconstructive Surgical Procedures -- Periodicals
617.95205 - Journal URLs:
- http://journals.lww.com/prsgo/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/GOX.0000000000001576 ↗
- Languages:
- English
- ISSNs:
- 2169-7574
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6076.xml