Cephalomedullary Nail Fixation of Intertrochanteric Femur Fractures: Are Two Proximal Screws Better Than One?. Issue 11 (November 2017)
- Record Type:
- Journal Article
- Title:
- Cephalomedullary Nail Fixation of Intertrochanteric Femur Fractures: Are Two Proximal Screws Better Than One?. Issue 11 (November 2017)
- Main Title:
- Cephalomedullary Nail Fixation of Intertrochanteric Femur Fractures
- Authors:
- Serrano, Rafael
Blair, James A.
Watson, David T.
Infante, Anthony F.
Shah, Anjan R.
Mir, Hassan R.
Maxson, Benjamin J.
Downes, Katheryne W.
Sanders, Roy W. - Abstract:
- Abstract : Objectives: To analyze radiographic changes in intertrochanteric (IT) fracture alignment after treatment with either a single sliding lag screw or an integrated compressed and locked, dual screw, cephalomedullary nail construct. Design: Retrospective comparative study. Setting: Level 1 regional trauma center. Patients: 1004 OTA/AO 31A, 31B2.1 fractures treated with either a single screw cephalomedullary nail (Gamma 3) or an integrated dual screw cephalomedullary nail (InterTAN) between February 1, 2005, and June 30, 2013. Four hundred thirteen remained after exclusion criteria; 130 were treated with a single screw device (79 stable and 51 unstable), and 283 with an integrated dual screw device (155 stable and 128 unstable). Intervention: Cephalomedullary nail insertion. Outcome Measures: Radiographic analysis included fracture pattern, fracture reduction, neck-shaft angle (NSA), and femoral neck shortening (FNS) differences at 3, 6, and 12 months. Measurements were normalized using known lag screw dimensions, digitally corrected for magnification. Rotation between x-rays was controlled using a ratio of known to measured dimensions. The Mann–Whitney U test was used for statistical analysis. Results: The single screw device resulted in 2.5 times more varus collapse (NSA) and 2 times more FNS over 1 year, as compared to the locked, integrated dual screw device, regardless of stability ( P < 0.001). NSA and FNS changes were greater for both devices in unstableAbstract : Objectives: To analyze radiographic changes in intertrochanteric (IT) fracture alignment after treatment with either a single sliding lag screw or an integrated compressed and locked, dual screw, cephalomedullary nail construct. Design: Retrospective comparative study. Setting: Level 1 regional trauma center. Patients: 1004 OTA/AO 31A, 31B2.1 fractures treated with either a single screw cephalomedullary nail (Gamma 3) or an integrated dual screw cephalomedullary nail (InterTAN) between February 1, 2005, and June 30, 2013. Four hundred thirteen remained after exclusion criteria; 130 were treated with a single screw device (79 stable and 51 unstable), and 283 with an integrated dual screw device (155 stable and 128 unstable). Intervention: Cephalomedullary nail insertion. Outcome Measures: Radiographic analysis included fracture pattern, fracture reduction, neck-shaft angle (NSA), and femoral neck shortening (FNS) differences at 3, 6, and 12 months. Measurements were normalized using known lag screw dimensions, digitally corrected for magnification. Rotation between x-rays was controlled using a ratio of known to measured dimensions. The Mann–Whitney U test was used for statistical analysis. Results: The single screw device resulted in 2.5 times more varus collapse (NSA) and 2 times more FNS over 1 year, as compared to the locked, integrated dual screw device, regardless of stability ( P < 0.001). NSA and FNS changes were greater for both devices in unstable fracture patterns, but significantly less movement occurred with the dual screw device ( P < 0.001). Conclusions: A cephalomedullary nail with 2 integrated proximal screws that can be compressed and then locked seems to maintain initial IT fracture reduction and subsequent position over time, with less varus collapse and less shortening than a single screw device. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence. Abstract : Supplemental Digital Content is Available in the Text. … (more)
- Is Part Of:
- Journal of orthopaedic trauma. Volume 31:Issue 11(2017)
- Journal:
- Journal of orthopaedic trauma
- Issue:
- Volume 31:Issue 11(2017)
- Issue Display:
- Volume 31, Issue 11 (2017)
- Year:
- 2017
- Volume:
- 31
- Issue:
- 11
- Issue Sort Value:
- 2017-0031-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-11
- Subjects:
- intertrochanteric femur fractures -- cephalomedullary nail -- Gamma 3 -- InterTAN -- femoral neck shortening -- varus collapse -- dual screw fixation -- unstable femur fractures
Orthopedics -- Periodicals
Wounds and injuries -- Periodicals
Orthopedics -- Periodicals
Wounds and Injuries -- therapy -- Periodicals
Periodicals
617.47044 - Journal URLs:
- http://journals.lww.com/jorthotrauma/pages/default.aspx ↗
http://www.jorthotrauma.com ↗
http://cufts2.lib.sfu.ca/CJDB/BVAS/journal/149202 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00005131-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BOT.0000000000000967 ↗
- Languages:
- English
- ISSNs:
- 0890-5339
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.675000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6061.xml