Bare-metal stents across the Vater's ampulla is a safe method for patients with lower bile duct obstruction. Issue 45 (November 2017)
- Record Type:
- Journal Article
- Title:
- Bare-metal stents across the Vater's ampulla is a safe method for patients with lower bile duct obstruction. Issue 45 (November 2017)
- Main Title:
- Bare-metal stents across the Vater's ampulla is a safe method for patients with lower bile duct obstruction
- Authors:
- Mao, Xiao-Nan
Lu, Zai-Ming
Wen, Feng
Liang, Hong-Yuan
Guo, Qi-Yong - Other Names:
- Phan. Phil section editor.
- Abstract:
- Abstract : Abstract: This study explored the effect of the implant position of stents across the Vater's ampulla on treatment outcomes in patients with lower bile duct obstruction. In the retrospective study, 41 patients with malignant obstruction of the lower bile duct and obstructive jaundice received percutaneous transhepatic biliary placement of bare-metal stents. Basic demographic data on patients, such as sex, age, and primary diseases, and follow-up data, including postoperative complications and jaundice-free survival, were recorded. The follow-up data on patients with an involved ampulla, patients with an uninvolved ampulla, patients with a stent across the ampulla, and patients with a stent at a site other than the ampulla were compared. Furthermore, prognostic factors for jaundice- free survival were investigated using Cox proportional hazards regression analysis. Among the 41 patients, 38 patients experienced subsiding of jaundice, whereas 3 cases had unsuccessful stent patency. Whether or not the ampulla was involved did not influence the incidence rates of postoperative complications and the jaundice-free survival time. Notably, when stents were placed across the ampulla, the jaundice-free survival time was significantly longer than when stents were placed at sites other than across the ampulla ( P < .05). Furthermore, placement of the stent across the ampulla or at other sites was an independent prognostic factor (hazard ratio = 0.154, 95% confidence intervalAbstract : Abstract: This study explored the effect of the implant position of stents across the Vater's ampulla on treatment outcomes in patients with lower bile duct obstruction. In the retrospective study, 41 patients with malignant obstruction of the lower bile duct and obstructive jaundice received percutaneous transhepatic biliary placement of bare-metal stents. Basic demographic data on patients, such as sex, age, and primary diseases, and follow-up data, including postoperative complications and jaundice-free survival, were recorded. The follow-up data on patients with an involved ampulla, patients with an uninvolved ampulla, patients with a stent across the ampulla, and patients with a stent at a site other than the ampulla were compared. Furthermore, prognostic factors for jaundice- free survival were investigated using Cox proportional hazards regression analysis. Among the 41 patients, 38 patients experienced subsiding of jaundice, whereas 3 cases had unsuccessful stent patency. Whether or not the ampulla was involved did not influence the incidence rates of postoperative complications and the jaundice-free survival time. Notably, when stents were placed across the ampulla, the jaundice-free survival time was significantly longer than when stents were placed at sites other than across the ampulla ( P < .05). Furthermore, placement of the stent across the ampulla or at other sites was an independent prognostic factor (hazard ratio = 0.154, 95% confidence interval 0.042–0.560, P = .005) for jaundice-free survival of patients. The current study revealed that the implant position of a stent across the ampulla resulted in maintenance of stent patency and prolongation of the jaundice-free survival time. … (more)
- Is Part Of:
- Medicine. Volume 96:Issue 45(2017)
- Journal:
- Medicine
- Issue:
- Volume 96:Issue 45(2017)
- Issue Display:
- Volume 96, Issue 45 (2017)
- Year:
- 2017
- Volume:
- 96
- Issue:
- 45
- Issue Sort Value:
- 2017-0096-0045-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-11
- Subjects:
- implant position of biliary stents -- jaundice-free survival -- malignant lower bile duct obstruction -- postoperative complications -- stents across ampulla
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000007475 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6055.xml