Head-to-Head Comparison of Global and Regional Two-Dimensional Speckle Tracking Strain Versus Cardiac Magnetic Resonance Tagging in a Multicenter Validation Study. (November 2017)
- Record Type:
- Journal Article
- Title:
- Head-to-Head Comparison of Global and Regional Two-Dimensional Speckle Tracking Strain Versus Cardiac Magnetic Resonance Tagging in a Multicenter Validation Study. (November 2017)
- Main Title:
- Head-to-Head Comparison of Global and Regional Two-Dimensional Speckle Tracking Strain Versus Cardiac Magnetic Resonance Tagging in a Multicenter Validation Study
- Authors:
- Amzulescu, Mihaela Silvia
Langet, Hélène
Saloux, Eric
Manrique, Alain
Boileau, Laurianne
Slimani, Alisson
Allain, Pascal
Roy, Clotilde
de Meester, Christophe
Pasquet, Agnès
De Craene, Mathieu
Vancraeynest, David
Pouleur, Anne-Catherine
Vanoverschelde, Jean-Louis J.
Gerber, Bernhard L. - Abstract:
- Abstract : Background—: Despite widespread use to characterize and refine prognosis, validation data of two-dimensional (2D) speckle tracking (2DST) echocardiography myocardial strain measurement remain scarce. Methods and Results—: Global and regional subendocardial peak-systolic Lagrangian longitudinal (LS) and circumferential strain (CS) by 2DST and 2D-tagged (2DTagg) cardiac magnetic resonance imaging were compared against sonomicrometry in a dynamic heart phantom and among each other in 136 patients included prospectively at 2 centers. The ability of regional LS and CS 2DST and 2DTagg to identify late gadolinium enhancement was compared using receiver operating characteristics curves. In vitro, both LS-2DST and 2DTagg highly agreed with sonomicrometry (intraclass correlation coefficient [ICC], 0.89 and ICC, 0.90, both P <0.001 with −3±2.8% and 0.34±4.35% bias, respectively). In patients, both global LS and global CS 2DST agreed well with 2DTagg (ICC, 0.89 and ICC, 0.80; P <0.001); however, they provided systematically greater values (relative bias of −37±27% and −25±37% for global LS and global CS, respectively). On regional basis, however, ICC (from 0.17 to 0.81) and relative bias (from −9 to −98%) between 2DST and 2DTagg varied strongly among segments. Ability to discriminate infarcted versus noninfarcted segments by late gadolinium enhancement was similarly good for regional LS 2DTagg and 2DST (area under the curve, 0.66 versus 0.59; P =0.08), while it was lower forAbstract : Background—: Despite widespread use to characterize and refine prognosis, validation data of two-dimensional (2D) speckle tracking (2DST) echocardiography myocardial strain measurement remain scarce. Methods and Results—: Global and regional subendocardial peak-systolic Lagrangian longitudinal (LS) and circumferential strain (CS) by 2DST and 2D-tagged (2DTagg) cardiac magnetic resonance imaging were compared against sonomicrometry in a dynamic heart phantom and among each other in 136 patients included prospectively at 2 centers. The ability of regional LS and CS 2DST and 2DTagg to identify late gadolinium enhancement was compared using receiver operating characteristics curves. In vitro, both LS-2DST and 2DTagg highly agreed with sonomicrometry (intraclass correlation coefficient [ICC], 0.89 and ICC, 0.90, both P <0.001 with −3±2.8% and 0.34±4.35% bias, respectively). In patients, both global LS and global CS 2DST agreed well with 2DTagg (ICC, 0.89 and ICC, 0.80; P <0.001); however, they provided systematically greater values (relative bias of −37±27% and −25±37% for global LS and global CS, respectively). On regional basis, however, ICC (from 0.17 to 0.81) and relative bias (from −9 to −98%) between 2DST and 2DTagg varied strongly among segments. Ability to discriminate infarcted versus noninfarcted segments by late gadolinium enhancement was similarly good for regional LS 2DTagg and 2DST (area under the curve, 0.66 versus 0.59; P =0.08), while it was lower for CS 2DST than 2DTagg (area under the curve, 0.61 versus 0.75; P <0.001). Conclusions—: The high accuracy against sonomicrometry and good agreement of global LS and global CS by 2DST and 2DTagg confirm the overall validity of 2DST strain measurement. Yet, higher intertechnique segmental variability and lower ability for detecting infarct suggest that 2DST strain estimates may be less performant on regional than on global basis. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 10:Number 11(2017)
- Journal:
- Circulation
- Issue:
- Volume 10:Number 11(2017)
- Issue Display:
- Volume 10, Issue 11 (2017)
- Year:
- 2017
- Volume:
- 10
- Issue:
- 11
- Issue Sort Value:
- 2017-0010-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-11
- Subjects:
- 2-dimensional -- magnetic resonance imaging -- software validation -- speckle tracking -- echocardiography -- strain
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.1075405 - Journal URLs:
- http://circimaging.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCIMAGING.117.006530 ↗
- Languages:
- English
- ISSNs:
- 1941-9651
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262750
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6071.xml