Effects of High-Flow Nasal Cannula on the Work of Breathing in Patients Recovering From Acute Respiratory Failure*. Issue 12 (December 2017)
- Record Type:
- Journal Article
- Title:
- Effects of High-Flow Nasal Cannula on the Work of Breathing in Patients Recovering From Acute Respiratory Failure*. Issue 12 (December 2017)
- Main Title:
- Effects of High-Flow Nasal Cannula on the Work of Breathing in Patients Recovering From Acute Respiratory Failure*
- Authors:
- Delorme, Mathieu
Bouchard, Pierre-Alexandre
Simon, Mathieu
Simard, Serge
Lellouche, François - Abstract:
- Abstract : Objectives: High-flow nasal cannula is increasingly used in the management of respiratory failure. However, little is known about its impact on respiratory effort, which could explain part of the benefits in terms of comfort and efficiency. This study was designed to assess the effects of high-flow nasal cannula on indexes of respiratory effort (i.e., esophageal pressure variations, esophageal pressure-time product/min, and work of breathing/min) in adults. Design: A randomized controlled crossover study was conducted in 12 patients with moderate respiratory distress (i.e., after partial recovery from an acute episode, allowing physiologic measurements). Setting: Institut Universitaire de Cardiologie et de Pneumologie de Québec, QC, Canada. Subjects: Twelve adult patients with respiratory distress symptoms were enrolled in this study. Interventions: Four experimental conditions were evaluated: baseline with conventional oxygen therapy and high-flow nasal cannula at 20, 40, and 60 L/min. The primary outcomes were the indexes of respiratory effort (i.e., esophageal pressure variations, esophageal pressure-time product/min, and work of breathing/min). Secondary outcomes included tidal volume, respiratory rate, minute volume, dynamic lung compliance, inspiratory resistance, and blood gases. Measurements and Main Results: Esophageal pressure variations decreased from 9.8 (5.8–14.6) cm H2 O at baseline to 4.9 (2.1–9.1) cm H2 O at 60 L/min ( p = 0.035). EsophagealAbstract : Objectives: High-flow nasal cannula is increasingly used in the management of respiratory failure. However, little is known about its impact on respiratory effort, which could explain part of the benefits in terms of comfort and efficiency. This study was designed to assess the effects of high-flow nasal cannula on indexes of respiratory effort (i.e., esophageal pressure variations, esophageal pressure-time product/min, and work of breathing/min) in adults. Design: A randomized controlled crossover study was conducted in 12 patients with moderate respiratory distress (i.e., after partial recovery from an acute episode, allowing physiologic measurements). Setting: Institut Universitaire de Cardiologie et de Pneumologie de Québec, QC, Canada. Subjects: Twelve adult patients with respiratory distress symptoms were enrolled in this study. Interventions: Four experimental conditions were evaluated: baseline with conventional oxygen therapy and high-flow nasal cannula at 20, 40, and 60 L/min. The primary outcomes were the indexes of respiratory effort (i.e., esophageal pressure variations, esophageal pressure-time product/min, and work of breathing/min). Secondary outcomes included tidal volume, respiratory rate, minute volume, dynamic lung compliance, inspiratory resistance, and blood gases. Measurements and Main Results: Esophageal pressure variations decreased from 9.8 (5.8–14.6) cm H2 O at baseline to 4.9 (2.1–9.1) cm H2 O at 60 L/min ( p = 0.035). Esophageal pressure-time product/min decreased from 165 (126–179) to 72 (54–137) cm H2 O s/min, respectively ( p = 0.033). Work of breathing/min decreased from 4.3 (3.5–6.3) to 2.1 (1.5–5.0) J/min, respectively ( p = 0.031). Respiratory pattern variables and capillary blood gases were not significantly modified between experimental conditions. Dynamic lung compliance increased from 38 (24–64) mL/cm H2 O at baseline to 59 (43–175) mL/cm H2 O at 60 L/min ( p = 0.007), and inspiratory resistance decreased from 9.6 (5.5–13.4) to 5.0 (1.0–9.1) cm H2 O/L/s, respectively ( p = 0.07). Conclusions: High-flow nasal cannula, when set at 60 L/min, significantly reduces the indexes of respiratory effort in adult patients recovering from acute respiratory failure. This effect is associated with an improvement in respiratory mechanics. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Critical care medicine. Volume 45:Issue 12(2017)
- Journal:
- Critical care medicine
- Issue:
- Volume 45:Issue 12(2017)
- Issue Display:
- Volume 45, Issue 12 (2017)
- Year:
- 2017
- Volume:
- 45
- Issue:
- 12
- Issue Sort Value:
- 2017-0045-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-12
- Subjects:
- high-flow nasal cannula -- oxygen therapy -- respiratory distress -- respiratory inductive plethysmography -- work of breathing
Critical care medicine -- Periodicals
Soins intensifs -- Périodiques
616.028 - Journal URLs:
- http://journals.lww.com/ccmjournal/Pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/CCM.0000000000002693 ↗
- Languages:
- English
- ISSNs:
- 0090-3493
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3487.451000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6056.xml