A Quantitative Analysis of Microcirculation in Skin Defects Covered with Topical Wound Dressings or a Newly Developed Collagen Matrix. (November 2017)
- Record Type:
- Journal Article
- Title:
- A Quantitative Analysis of Microcirculation in Skin Defects Covered with Topical Wound Dressings or a Newly Developed Collagen Matrix. (November 2017)
- Main Title:
- A Quantitative Analysis of Microcirculation in Skin Defects Covered with Topical Wound Dressings or a Newly Developed Collagen Matrix
- Authors:
- Held, Manuel
Medved, Fabian
Petersen, Wiebke
Tolzmann, Dascha Sophie
Rahmanian-Schwarz, Afshin
Schaller, Hans-Eberhard
Rothenberger, Jens - Abstract:
- ABSTRACT: OBJECTIVE: Innovative skin substitutes and temporary wound dressings are frequently used in the treatment of superficial and partial-thickness wounds. The aim of this study was to compare 2 commonly used temporary skin dressings with a newly developed collagen matrix to determine changes in microcirculation as measured by blood flow, hemoglobin oxygenation, and relative hemoglobin values during healing of partial-thickness skin defects. METHODS: This animal study involved 28 adult male Lewis rats. On the back of each rat, 2 standardized partial-thickness skin defects were generated through a skin dermatome (n = 56). Then, wounds were treated with polylactide-based copolymer skin substitute (Suprathel, PolyMedics, Denkendorf, Germany; n = 14), biosynthetic skin dressing (Biobrane, Smith & Nephew, Hamburg, Germany; n = 14), or Collagen Cell Carrier (CCC; Naturin Viscofan, Weinheim, Germany; n = 14). The remaining control wounds were left untreated (n = 14). MAIN OUTCOME MEASURES: Perfusion dynamics were assessed every 10 days for 80 days with the O2C device (LEA Medizintechnik, Gieβen, Germany) to determine blood flow, hemoglobin oxygenation, and relative amount of hemoglobin. MAIN RESULTS: Blood flow was increased in all wounds for at least 30 days after wound generation. The relative amounts of hemoglobin were increased in superficial layers (2 mm) for 10 to 20 days. Hemoglobin oxygenation in the superficial layers decreased in the polylactide-based copolymer skinABSTRACT: OBJECTIVE: Innovative skin substitutes and temporary wound dressings are frequently used in the treatment of superficial and partial-thickness wounds. The aim of this study was to compare 2 commonly used temporary skin dressings with a newly developed collagen matrix to determine changes in microcirculation as measured by blood flow, hemoglobin oxygenation, and relative hemoglobin values during healing of partial-thickness skin defects. METHODS: This animal study involved 28 adult male Lewis rats. On the back of each rat, 2 standardized partial-thickness skin defects were generated through a skin dermatome (n = 56). Then, wounds were treated with polylactide-based copolymer skin substitute (Suprathel, PolyMedics, Denkendorf, Germany; n = 14), biosynthetic skin dressing (Biobrane, Smith & Nephew, Hamburg, Germany; n = 14), or Collagen Cell Carrier (CCC; Naturin Viscofan, Weinheim, Germany; n = 14). The remaining control wounds were left untreated (n = 14). MAIN OUTCOME MEASURES: Perfusion dynamics were assessed every 10 days for 80 days with the O2C device (LEA Medizintechnik, Gieβen, Germany) to determine blood flow, hemoglobin oxygenation, and relative amount of hemoglobin. MAIN RESULTS: Blood flow was increased in all wounds for at least 30 days after wound generation. The relative amounts of hemoglobin were increased in superficial layers (2 mm) for 10 to 20 days. Hemoglobin oxygenation in the superficial layers decreased in the polylactide-based copolymer skin substitute and biosynthetic skin dressing–treated groups and initially increased in the untreated wounds and CCC groups on day 10; these values also decreased. CONCLUSIONS: The presented results demonstrate the complex changes in microcirculation in the course of healing partial-thickness wounds with different wound dressings and contribute to a better understanding of these wounds. However, based on the results of the study, a clear recommendation for a specific substitute is not yet possible. … (more)
- Is Part Of:
- Advances in skin & wound care. Volume 30:Number 11(2017)
- Journal:
- Advances in skin & wound care
- Issue:
- Volume 30:Number 11(2017)
- Issue Display:
- Volume 30, Issue 11 (2017)
- Year:
- 2017
- Volume:
- 30
- Issue:
- 11
- Issue Sort Value:
- 2017-0030-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-11
- Subjects:
- biosynthetic skin dressing -- collagen cell carrier -- hemoglobin -- microcirculation -- partial-thickness skin defect -- polylactide-based copolymer skin substitute
Wounds and injuries -- Treatment -- Periodicals
Wound healing -- Periodicals
Skin -- Diseases -- Treatment -- Periodicals
Dermatology -- United States -- Periodicals
617.106 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00129334-000000000-00000 ↗
http://infotrac.galegroup.com/itweb/lcml_main ↗
http://www.woundcarejournal.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/01.ASW.0000525848.21221.b8 ↗
- Languages:
- English
- ISSNs:
- 1527-7941
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0711.389000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6071.xml