Chest CT with iterative reconstruction algorithms for airway stent evaluation in patients with malignant obstructive tracheobronchial diseases. Issue 39 (September 2016)
- Record Type:
- Journal Article
- Title:
- Chest CT with iterative reconstruction algorithms for airway stent evaluation in patients with malignant obstructive tracheobronchial diseases. Issue 39 (September 2016)
- Main Title:
- Chest CT with iterative reconstruction algorithms for airway stent evaluation in patients with malignant obstructive tracheobronchial diseases
- Authors:
- Li, Tingting
Zhang, Yonggao
Wang, Yadong
Gao, Jianbo
Jiang, Yan - Other Names:
- Liu. Jian section editor.
- Abstract:
- Abstract : Abstract: The aim of the study was to investigate the image quality of low-dose CT images with different reconstruction algorithms including filtered back projection (FBP), hybrid iterative reconstruction (HIR), and iterative model reconstruction (IMR) algorithms by comparison of routine dose images with FBP reconstruction, in patients with malignant obstructive tracheobronchial diseases. In total, 60 patients (59 ± 9.3 years, 37 males) with airway stent who are randomly assigned into 2 groups (routine-dose [RD] and low-dose [LD] group, 30 for each) underwent chest CT on a 256-slice CT (RD-group 120 kV, 250 mAs, LD-group 120 kV, 120 mAs). Images were reconstructed with filtered back projection (FBP) algorithm in the RD group, whereas with FBP, HIR and IMR algorithms in the LD group. Effective radiation dose of both groups was recorded. Image-quality assessment was performed by 2 radiologists according to structure demarcation near stents, artifacts, noise, and diagnostic confidence using a 5-point scale (1 [poor] to 5 [excellent]). Image noise and CNR were measured. The effective radiation dose of LD group was reduced 52.7% compared with the RD group (10.8 mSv ± 0.58 vs 5.1 mSv ± 0.26, P = 0.00). LD-IMR images enabled lowest image noise and best subjective image quality scores of all 4 indices, when compared with RD images reconstructed with FBP (RD-FBP) images (all P < 0.05). LD images reconstructed with and with HIR (LD-HIR) images enabled higher score inAbstract : Abstract: The aim of the study was to investigate the image quality of low-dose CT images with different reconstruction algorithms including filtered back projection (FBP), hybrid iterative reconstruction (HIR), and iterative model reconstruction (IMR) algorithms by comparison of routine dose images with FBP reconstruction, in patients with malignant obstructive tracheobronchial diseases. In total, 60 patients (59 ± 9.3 years, 37 males) with airway stent who are randomly assigned into 2 groups (routine-dose [RD] and low-dose [LD] group, 30 for each) underwent chest CT on a 256-slice CT (RD-group 120 kV, 250 mAs, LD-group 120 kV, 120 mAs). Images were reconstructed with filtered back projection (FBP) algorithm in the RD group, whereas with FBP, HIR and IMR algorithms in the LD group. Effective radiation dose of both groups was recorded. Image-quality assessment was performed by 2 radiologists according to structure demarcation near stents, artifacts, noise, and diagnostic confidence using a 5-point scale (1 [poor] to 5 [excellent]). Image noise and CNR were measured. The effective radiation dose of LD group was reduced 52.7% compared with the RD group (10.8 mSv ± 0.58 vs 5.1 mSv ± 0.26, P = 0.00). LD-IMR images enabled lowest image noise and best subjective image quality scores of all 4 indices, when compared with RD images reconstructed with FBP (RD-FBP) images (all P < 0.05). LD images reconstructed with and with HIR (LD-HIR) images enabled higher score in subjective image quality of artifacts ( P < 0.05), whereas it showed no difference in the other subjective image-quality indices and image noise. Significant higher image noise and lower score of subjective image quality were observed in LD-FBP images (all P < 0.05). Both IMR and HIR improved image quality of low-dose chest CT by comparison of routine dose images reconstructed with FBP. Meanwhile, IMR allows further image quality improvement than HIR. … (more)
- Is Part Of:
- Medicine. Volume 95:Issue 39(2016)
- Journal:
- Medicine
- Issue:
- Volume 95:Issue 39(2016)
- Issue Display:
- Volume 95, Issue 39 (2016)
- Year:
- 2016
- Volume:
- 95
- Issue:
- 39
- Issue Sort Value:
- 2016-0095-0039-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- airway stent -- Iterative model reconstruction -- low dose -- multi-detector computed tomography
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000004873 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6042.xml