Hydrophobic and hydrophilic effects on water structuring and adhesion in denture adhesives. Issue 5 (31st January 2018)
- Record Type:
- Journal Article
- Title:
- Hydrophobic and hydrophilic effects on water structuring and adhesion in denture adhesives. Issue 5 (31st January 2018)
- Main Title:
- Hydrophobic and hydrophilic effects on water structuring and adhesion in denture adhesives
- Authors:
- Gill, Simrone K.
Roohpour, Nima
An, Yiran
Gautrot, Julien E.
Topham, Paul D.
Tighe, Brian J. - Abstract:
- Abstract: Denture adhesives are designed to be moisture‐sensitive through the inclusion of a blend of polymer salts with varying degrees of water‐sensitivity. This enables the adhesive to mix with saliva in vivo and activate its high tack, through the formation of a mucilaginous layer. We report for the first time, the use of differential scanning calorimetry to study a series of hydrophobic and hydrophilic polymeric systems in order to correlate water‐structuring behavior with adhesion strength. Adhesive bonding of the more hydrophobic variants was higher than that of a commercial‐based control and a more hydrophilic polymer system in both lap shear and tensile configurations. Water‐binding data suggested that increasing the hydrophobicity of the maleic acid copolymer substituents led to decreased levels of freezing water. In comparison, increasing the hydrophilic nature of the polymer backbone gave higher levels of freezing water within the hydrated samples. The results of this study emphasize the importance of varying the levels of hydrophobic and hydrophilic components within denture adhesive formulations, alongside the types of water present within the adhesive systems. This phenomenon has shown the potential to fine‐tune the adhesive properties and failure mode against poly(methyl methacrylate), surfaces. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1355–1362, 2018.
- Is Part Of:
- Journal of biomedical materials research. Volume 106:Issue 5(2018)
- Journal:
- Journal of biomedical materials research
- Issue:
- Volume 106:Issue 5(2018)
- Issue Display:
- Volume 106, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 106
- Issue:
- 5
- Issue Sort Value:
- 2018-0106-0005-0000
- Page Start:
- 1355
- Page End:
- 1362
- Publication Date:
- 2018-01-31
- Subjects:
- polymers -- adhesives -- prosthodontics -- water‐structuring -- differential scanning calorimetry
Biomedical materials -- Periodicals
610.28 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1552-4965 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jbm.a.36341 ↗
- Languages:
- English
- ISSNs:
- 1549-3296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.720000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6028.xml