Does Location of Rotation Center in Artificial Disc Affect Cervical Biomechanics?. Issue 8 (15th April 2015)
- Record Type:
- Journal Article
- Title:
- Does Location of Rotation Center in Artificial Disc Affect Cervical Biomechanics?. Issue 8 (15th April 2015)
- Main Title:
- Does Location of Rotation Center in Artificial Disc Affect Cervical Biomechanics?
- Authors:
- Mo, Zhongjun
Zhao, Yanbin
Du, Chengfei
Sun, Yu
Zhang, Ming
Fan, Yubo - Abstract:
- Abstract : Study Design: A 3-dimensional finite element investigation. Objective: To compare the biomechanical performances of different rotation centers (RCs) in the prevalent artificial cervical discs. Summary of Background Data: Various configurations are applied in artificial discs. Design parameters may influence the biomechanics of implanted spine. The RC is a primary variation in the popular artificial discs. Methods: Implantation of 5 prostheses was simulated at C5–C6 on the basis of a validated finite element cervical model (C3–C7). The prostheses included ball-in-socket design with a fixed RC located on the inferior endplate (BS-FI) and on the superior endplate (BS-FS), with a mobile RC at the inferior endplate (BS-MI), dual articulation with a mobile RC between the endplates (DA-M), and sliding articulation with various RCs (SA-V). The spinal motions in flexion and extension served as a displacement loading at the C3 vertebrae. Results: Total disc replacements reduced extension moment. The ball-in-socket designs required less flexion moment, whereas the flexion stiffness of the spines with DA-M and SA-V was similar to that of the healthy model. The contributions of the implanted level to the global motions increased in the total disc replacements, except in the SA-V and DA-M models (in flexion). Ball-in-socket designs produced severe stress distributions in facet cartilage, whereas DA-M and SA-V produced more severe stress distribution on the bone-implantAbstract : Study Design: A 3-dimensional finite element investigation. Objective: To compare the biomechanical performances of different rotation centers (RCs) in the prevalent artificial cervical discs. Summary of Background Data: Various configurations are applied in artificial discs. Design parameters may influence the biomechanics of implanted spine. The RC is a primary variation in the popular artificial discs. Methods: Implantation of 5 prostheses was simulated at C5–C6 on the basis of a validated finite element cervical model (C3–C7). The prostheses included ball-in-socket design with a fixed RC located on the inferior endplate (BS-FI) and on the superior endplate (BS-FS), with a mobile RC at the inferior endplate (BS-MI), dual articulation with a mobile RC between the endplates (DA-M), and sliding articulation with various RCs (SA-V). The spinal motions in flexion and extension served as a displacement loading at the C3 vertebrae. Results: Total disc replacements reduced extension moment. The ball-in-socket designs required less flexion moment, whereas the flexion stiffness of the spines with DA-M and SA-V was similar to that of the healthy model. The contributions of the implanted level to the global motions increased in the total disc replacements, except in the SA-V and DA-M models (in flexion). Ball-in-socket designs produced severe stress distributions in facet cartilage, whereas DA-M and SA-V produced more severe stress distribution on the bone-implant interface. Conclusion: Cervical stability was extremely affected in extension and partially affected in flexion by total disc replacement. With the prostheses with mobile RC, cervical curvature was readjusted under a low follower load. The SA-V and BS-FS designs exhibited better performances in the entire segmental stiffness and in the stability of the operative level than the BS-MI and BS-FI designs in flexion. The 5 designs demonstrated varying advantages relative to the stress distribution in the facet cartilages and on the bone-implant interface. Level of Evidence: 5 Abstract : Implantations of 5 prostheses with different rotation centers were simulated. The results revealed that the location of the rotation center does effect cervical biomechanics. The ball-in-socket with fixed rotation center performed best in providing stability and stiffness, whereas sliding articulation exhibited better ability in relieving the facet cartilage stress. … (more)
- Is Part Of:
- Spine. Volume 40:Issue 8(2015)
- Journal:
- Spine
- Issue:
- Volume 40:Issue 8(2015)
- Issue Display:
- Volume 40, Issue 8 (2015)
- Year:
- 2015
- Volume:
- 40
- Issue:
- 8
- Issue Sort Value:
- 2015-0040-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-04-15
- Subjects:
- cervical disc replacement -- rotation center -- cervical kinematics -- stiffness -- facet stress
Spine -- Abnormalities -- Periodicals
Spine -- Diseases -- Periodicals
Spine -- Surgery -- Periodicals
616.73005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00007632-000000000-00000 ↗
http://journals.lww.com/spinejournal/pages/default.aspx ↗
http://www.spinejournal.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BRS.0000000000000818 ↗
- Languages:
- English
- ISSNs:
- 0362-2436
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8413.903000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6010.xml