Reduced acoustic noise in diffusion tensor imaging on a compact MRI system. Issue 6 (2nd October 2017)
- Record Type:
- Journal Article
- Title:
- Reduced acoustic noise in diffusion tensor imaging on a compact MRI system. Issue 6 (2nd October 2017)
- Main Title:
- Reduced acoustic noise in diffusion tensor imaging on a compact MRI system
- Authors:
- Tan, Ek T.
Hardy, Christopher J.
Shu, Yunhong
In, Myung‐Ho
Guidon, Arnaud
Huston, John
Bernstein, Matt A.
K.F. Foo, Thomas - Abstract:
- Abstract : Purpose: To investigate the feasibility of substantially reducing acoustic noise while performing diffusion tensor imaging (DTI) on a compact 3T (C3T) MRI scanner equipped with a 42‐cm inner‐diameter asymmetric gradient. Methods: A‐weighted acoustic measurements were made using 10 mT/m‐amplitude sinusoidal waveforms, corresponding to echo‐planar imaging (EPI) echo spacing of 0.25 to 5.0 ms, on a conventional, whole‐body 3T MRI and on the C3T. Acoustic measurements of DTI with trapezoidal EPI waveforms were then made at peak gradient performance on the C3T (80 mT/m amplitude, 700 T/m/s slew rate) and at derated performance (33 mT/m, 10 to 50 T/m/s) for acoustic noise reduction. DTI was acquired in two different phantoms and in seven human subjects, with and without gradient‐derating corresponding to multi‐ and single‐shot acquisitions, respectively. Results: Sinusoidal waveforms on the C3T were quieter by 8.5 to 15.6 A‐weighted decibels (dBA) on average as compared to the whole‐body MRI. The derated multishot DTI acquisition noise level was only 8.7 dBA (at 13 T/m/s slew rate) above ambient, and was quieter than non‐derated, single‐shot DTI by 22.3 dBA; however, the scan time was almost quadrupled. Although derating resulted in negligible diffusivity differences in the phantoms, small biases in diffusivity measurements were observed in human subjects (apparent diffusion coefficient = +9.3 ± 8.8%, fractional anisotropy = +3.2 ± 11.2%, radialAbstract : Purpose: To investigate the feasibility of substantially reducing acoustic noise while performing diffusion tensor imaging (DTI) on a compact 3T (C3T) MRI scanner equipped with a 42‐cm inner‐diameter asymmetric gradient. Methods: A‐weighted acoustic measurements were made using 10 mT/m‐amplitude sinusoidal waveforms, corresponding to echo‐planar imaging (EPI) echo spacing of 0.25 to 5.0 ms, on a conventional, whole‐body 3T MRI and on the C3T. Acoustic measurements of DTI with trapezoidal EPI waveforms were then made at peak gradient performance on the C3T (80 mT/m amplitude, 700 T/m/s slew rate) and at derated performance (33 mT/m, 10 to 50 T/m/s) for acoustic noise reduction. DTI was acquired in two different phantoms and in seven human subjects, with and without gradient‐derating corresponding to multi‐ and single‐shot acquisitions, respectively. Results: Sinusoidal waveforms on the C3T were quieter by 8.5 to 15.6 A‐weighted decibels (dBA) on average as compared to the whole‐body MRI. The derated multishot DTI acquisition noise level was only 8.7 dBA (at 13 T/m/s slew rate) above ambient, and was quieter than non‐derated, single‐shot DTI by 22.3 dBA; however, the scan time was almost quadrupled. Although derating resulted in negligible diffusivity differences in the phantoms, small biases in diffusivity measurements were observed in human subjects (apparent diffusion coefficient = +9.3 ± 8.8%, fractional anisotropy = +3.2 ± 11.2%, radial diffusivity = +9.4 ± 16.8%, parallel diffusivity = +10.3 ± 8.4%). Conclusion: The feasibility of achieving reduced acoustic noise levels with whole‐brain DTI on the C3T MRI was demonstrated. Magn Reson Med 79:2902–2911, 2018. © 2017 International Society for Magnetic Resonance in Medicine. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 79:Issue 6(2018)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 79:Issue 6(2018)
- Issue Display:
- Volume 79, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 79
- Issue:
- 6
- Issue Sort Value:
- 2018-0079-0006-0000
- Page Start:
- 2902
- Page End:
- 2911
- Publication Date:
- 2017-10-02
- Subjects:
- silent MRI -- diffusion tensor imaging -- compact 3T -- head‐only gradient
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26949 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6007.xml