Left ventricular outflow tract shape after aortic valve replacement with St. Jude Trifecta prosthesis. Issue 3 (22nd December 2017)
- Record Type:
- Journal Article
- Title:
- Left ventricular outflow tract shape after aortic valve replacement with St. Jude Trifecta prosthesis. Issue 3 (22nd December 2017)
- Main Title:
- Left ventricular outflow tract shape after aortic valve replacement with St. Jude Trifecta prosthesis
- Authors:
- Barletta, Giuseppe
Venditti, Francesco
Stefano, Pierluigi
Del Bene, Riccarda
Di Mario, Carlo - Abstract:
- Abstract : Background: Aortic prosthesis area (EOA) is computed by continuity equation from left ventricular (LV) stroke volume (SV) derived from LV outflow tract diameter (LVOTD ) or, when unmeasurable, from LV volumes (SVV ). There is evidence to suggest LVOT ellipticity and recommend 3D LVOT area (LVOTCSA ) adoption in aortic stenosis. We sought to evaluate if the same concept applies to supra‐annular aortic prosthesis comparing SV and EOA derived from LVOTD (EOAD ) and from LVOTCSA (EOACSA ). EOA computed from SVV (EAOV ) accuracy was evaluated in this setting. Patient‐prosthesis mismatch (PPM) was compared among different EOA computations. Methods: A consecutive series of 202 patients (aged 81 ± 4 years, 43% males) underwent St.Jude Trifecta aortic valve replacement (AVR) and were followed up with echocardiography at one‐year (335 ± 31 days). All measurements followed the EACVI or ASE guidelines, 3D X‐plane modality was used to compute SVv and measure LVOTCSA ; SV was calculated from LVOTD (SVD ) and LVOTCSA (SVCSA ). PPM was indexed EOA <0.65 cm²/m². Results: LVOT showed a significant ellipticity index (1.17 ± .27), independent of prosthesis size. EOAD (1.70 ± 0.55 cm²) was less than EOACSA (1.95 ± 0.62 cm²) ( P < .0001). SVV was significantly lower than SVD and SVCSA . Bland–Altman analysis showed a significant correlation between SVV and SVD or SVCSA although with large bias and imprecision. The correlations improved reducing bias and imprecision when LVOTAbstract : Background: Aortic prosthesis area (EOA) is computed by continuity equation from left ventricular (LV) stroke volume (SV) derived from LV outflow tract diameter (LVOTD ) or, when unmeasurable, from LV volumes (SVV ). There is evidence to suggest LVOT ellipticity and recommend 3D LVOT area (LVOTCSA ) adoption in aortic stenosis. We sought to evaluate if the same concept applies to supra‐annular aortic prosthesis comparing SV and EOA derived from LVOTD (EOAD ) and from LVOTCSA (EOACSA ). EOA computed from SVV (EAOV ) accuracy was evaluated in this setting. Patient‐prosthesis mismatch (PPM) was compared among different EOA computations. Methods: A consecutive series of 202 patients (aged 81 ± 4 years, 43% males) underwent St.Jude Trifecta aortic valve replacement (AVR) and were followed up with echocardiography at one‐year (335 ± 31 days). All measurements followed the EACVI or ASE guidelines, 3D X‐plane modality was used to compute SVv and measure LVOTCSA ; SV was calculated from LVOTD (SVD ) and LVOTCSA (SVCSA ). PPM was indexed EOA <0.65 cm²/m². Results: LVOT showed a significant ellipticity index (1.17 ± .27), independent of prosthesis size. EOAD (1.70 ± 0.55 cm²) was less than EOACSA (1.95 ± 0.62 cm²) ( P < .0001). SVV was significantly lower than SVD and SVCSA . Bland–Altman analysis showed a significant correlation between SVV and SVD or SVCSA although with large bias and imprecision. The correlations improved reducing bias and imprecision when LVOT time–velocity integral was <20 cm. PPM incidence was higher in EOAV (15.6%) compared to EOAD ( P = .04) or EOACSA ( P < .001). Conclusions: In supra‐annular AVR, LVOT retains its elliptical shape and LVOTCSA yielded larger prosthesis EOA with lower PPM incidence. PPM may be overestimated by EOAV . … (more)
- Is Part Of:
- Echocardiography. Volume 35:Issue 3(2018)
- Journal:
- Echocardiography
- Issue:
- Volume 35:Issue 3(2018)
- Issue Display:
- Volume 35, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 35
- Issue:
- 3
- Issue Sort Value:
- 2018-0035-0003-0000
- Page Start:
- 329
- Page End:
- 336
- Publication Date:
- 2017-12-22
- Subjects:
- aortic stenosis -- aortic valve prosthesis -- aortic valve replacement -- three‐dimensional transthoracic echocardiography
Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.13778 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5999.xml