Impact of a Digital Power Line Filter in the 2-Global-Flash Multifocal Electroretinogram of Glaucoma Patients Compared to Controls*. (2nd January 2016)
- Record Type:
- Journal Article
- Title:
- Impact of a Digital Power Line Filter in the 2-Global-Flash Multifocal Electroretinogram of Glaucoma Patients Compared to Controls*. (2nd January 2016)
- Main Title:
- Impact of a Digital Power Line Filter in the 2-Global-Flash Multifocal Electroretinogram of Glaucoma Patients Compared to Controls*
- Authors:
- Ledolter, Anna A.
Todorova, Margarita G.
Schoetzau, Andreas
Palmowski-Wolfe, Anja M. - Abstract:
- Abstract: Purpose : To assess the effect of a 50 Hz power line digital filter on the response to a 2-global-flash multifocal electroretinogram (mfERG) in primary open angle glaucoma (POAG) compared to control. Materials and methods : A 2-global-flash mfERG (VERIS™) was recorded (23 control, 34 POAG). Eight recordings were noise contaminated: 4 control, 4 POAG. Response averages from the central 10° and 7 surrounding groups were analyzed with and without a 50 Hz digital filter for the following mfERG response epochs: direct component (15–45 ms), 1st (45–75 ms) and 2nd (75–105 ms) induced components. Results : A digital 50 Hz filter had little effect on uncontaminated with noise waveforms but, in noisy recordings, changed the waveform dramatically to resemble uncontaminated waveforms. In controls' 50 Hz-filtered uncontaminated with noise mfERGs differed significantly from unfiltered responses in induced components. Uncontaminated with noise recordings from glaucoma patients did not differ with or without the notch filter ( p > 0.1 for all three epochs of mfERG). The mfERG response in the central 10°in glaucoma patients differed significantly from controls, whether the notch filter was used or not ( p < 0.001). Conclusions : A 50 Hz notch filter allows grossly contaminated waveforms to be analyzed in a meaningful manner. With a 50 Hz filter, glaucoma patients still differed significantly from normal.
- Is Part Of:
- Current eye research. Volume 41:Number 1(2016:Jan.)
- Journal:
- Current eye research
- Issue:
- Volume 41:Number 1(2016:Jan.)
- Issue Display:
- Volume 41, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 41
- Issue:
- 1
- Issue Sort Value:
- 2016-0041-0001-0000
- Page Start:
- 70
- Page End:
- 78
- Publication Date:
- 2016-01-02
- Subjects:
- 50 Hz -- digital power line filter -- glaucoma -- multifocal ERG -- notch filter
Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
Ophthalmology -- Periodicals
573.88 - Journal URLs:
- http://informahealthcare.com/journal/cey ↗
http://www.tandfonline.com/toc/icey20/current ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/02713683.2014.1002043 ↗
- Languages:
- English
- ISSNs:
- 0271-3683
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3496.570000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6002.xml