Clinical outcomes after upgrading from pacemakers to cardiac resynchronization therapy. Issue 3 (16th February 2018)
- Record Type:
- Journal Article
- Title:
- Clinical outcomes after upgrading from pacemakers to cardiac resynchronization therapy. Issue 3 (16th February 2018)
- Main Title:
- Clinical outcomes after upgrading from pacemakers to cardiac resynchronization therapy
- Authors:
- Leyva, Francisco
Zegard, Abbasin
Patel, Kiran
Panting, Jonathan
Marshall, Howard
Qiu, Tian - Abstract:
- Abstract: Background and aims: Right ventricular pacing may lead to heart failure (HF). Upgrades from pacemakers to cardiac resynchronization therapy (CRT) were excluded from most randomized, controlled trials. We sought to determine the long‐term outcomes of upgrading from pacemakers to CRT with (CRT‐D) or without (CRT‐P) defibrillation in patients with no history of sustained ventricular arrhythmias. Methods and results: In this observational study, clinical events were quantified in relation to the type of implant ( de novo or upgrade) and device type at upgrade (CRT‐P or CRT‐D). Patients underwent CRT implantation (n = 1, 545; 1, 314 [85%] de novo implants and 231 [15%] upgrades) over a median of 4.6 years [interquartile range: 2.4–7.0]. In analyses of crude event rates, upgrades had a higher total mortality (adjusted hazard ratio [aHR]: 1.33; 95% confidence interval [CI] 0.10–1.61), a higher total mortality or HF hospitalization (aHR: 1.26; 95% CI 1.05–1.51), but similar mortality or hospitalization for major adverse cardiac events (MACEs, aHR: 1.15; 95% CI 0.96–1.38). No group differences emerged in any of these endpoints after propensity score matching. After inverse probability weighting in upgrades, total mortality (HR: 0.55; 95% CI 0.36–0.73), total mortality or HF hospitalization (HR: 0.56; 95% CI 0.34–0.79), and total mortality or hospitalization for MACEs (HR: 0.61; 95% CI 0.40–0.82) were lower after CRT‐D than after CRT‐P. Conclusion: Upgrading from pacemakersAbstract: Background and aims: Right ventricular pacing may lead to heart failure (HF). Upgrades from pacemakers to cardiac resynchronization therapy (CRT) were excluded from most randomized, controlled trials. We sought to determine the long‐term outcomes of upgrading from pacemakers to CRT with (CRT‐D) or without (CRT‐P) defibrillation in patients with no history of sustained ventricular arrhythmias. Methods and results: In this observational study, clinical events were quantified in relation to the type of implant ( de novo or upgrade) and device type at upgrade (CRT‐P or CRT‐D). Patients underwent CRT implantation (n = 1, 545; 1, 314 [85%] de novo implants and 231 [15%] upgrades) over a median of 4.6 years [interquartile range: 2.4–7.0]. In analyses of crude event rates, upgrades had a higher total mortality (adjusted hazard ratio [aHR]: 1.33; 95% confidence interval [CI] 0.10–1.61), a higher total mortality or HF hospitalization (aHR: 1.26; 95% CI 1.05–1.51), but similar mortality or hospitalization for major adverse cardiac events (MACEs, aHR: 1.15; 95% CI 0.96–1.38). No group differences emerged in any of these endpoints after propensity score matching. After inverse probability weighting in upgrades, total mortality (HR: 0.55; 95% CI 0.36–0.73), total mortality or HF hospitalization (HR: 0.56; 95% CI 0.34–0.79), and total mortality or hospitalization for MACEs (HR: 0.61; 95% CI 0.40–0.82) were lower after CRT‐D than after CRT‐P. Conclusion: Upgrading from pacemakers to CRT was associated with a similar long‐term risk of mortality and morbidity to de novo CRT. After upgrade, CRT‐D was associated with a lower mortality than CRT‐P. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 41:Issue 3(2018)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 41:Issue 3(2018)
- Issue Display:
- Volume 41, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 41
- Issue:
- 3
- Issue Sort Value:
- 2018-0041-0003-0000
- Page Start:
- 290
- Page End:
- 298
- Publication Date:
- 2018-02-16
- Subjects:
- cardiac resynchronization therapy -- device upgrade -- implantable cardioverter defibrillators -- pacemakers
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.13287 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5988.xml