Determination of herbicides in environmental water samples by simultaneous in‐syringe magnetic stirring‐assisted dispersive liquid–liquid microextraction and silylation followed by GC–MS. Issue 5 (2nd January 2018)
- Record Type:
- Journal Article
- Title:
- Determination of herbicides in environmental water samples by simultaneous in‐syringe magnetic stirring‐assisted dispersive liquid–liquid microextraction and silylation followed by GC–MS. Issue 5 (2nd January 2018)
- Main Title:
- Determination of herbicides in environmental water samples by simultaneous in‐syringe magnetic stirring‐assisted dispersive liquid–liquid microextraction and silylation followed by GC–MS
- Authors:
- Suárez, Ruth
Clavijo, Sabrina
González, Alba
Cerdà, Víctor - Abstract:
- Abstract: An on‐line, fast, simple, selective, and sensitive method has been developed for the determination of three herbicides belonging to the following families: triazines (atrazine), chloroacetamide (alachlor), and phenoxy (2, 4‐dichlorophenoxyacetic acid) in water samples. The method involves an in‐syringe magnetic stirring‐assisted dispersive liquid–liquid microextraction along with simultaneous silylation prior to their determination by gas chromatography with mass spectrometry. Extraction, derivatization, and preconcentration have been simultaneously performed using acetone as dispersive solvent, N ‐methyl‐ N ‐ tert ‐butyldimethylsilyltrifluoroacetamide as derivatization agent and trichloroethylene as extraction solvent. After stirring for 180 s, the sedimented phase was transferred to a rotary micro‐volume injection valve (3 μL) and introduced by an air stream into gas chromatograph with mass spectrometry detector. Recovery and enrichment factors were 87.2–111.2% and 7.4–10.4, respectively. Relative standard deviations were in the ranges of 6.6–7.4 for intraday and 9.2–9.6 for interday precision. The detection limits were in the range of 0.045–0.03 μg/L, and good linearity was observed up to 200 μg/L, with R 2 ranging between 0.9905 and 0.9964. The developed method was satisfactorily applied to assess the occurrence of the studied herbicides in groundwater samples. The recovery test was also performed with values between 77 and 117%.
- Is Part Of:
- Journal of separation science. Volume 41:Issue 5(2018)
- Journal:
- Journal of separation science
- Issue:
- Volume 41:Issue 5(2018)
- Issue Display:
- Volume 41, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 41
- Issue:
- 5
- Issue Sort Value:
- 2018-0041-0005-0000
- Page Start:
- 1096
- Page End:
- 1103
- Publication Date:
- 2018-01-02
- Subjects:
- aqueous silylation -- dispersive liquid–liquid microextraction -- groundwater -- herbicides
Separation (Technology) -- Periodicals
Chromatographic analysis -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1615-9314 ↗
http://www.interscience.wiley.com/jpages/1615-9306 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jssc.201700875 ↗
- Languages:
- English
- ISSNs:
- 1615-9306
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5063.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5997.xml