PREVALENCE OF RETICULAR PSEUDODRUSEN IN AGE-RELATED MACULAR DEGENERATION USING MULTIMODAL IMAGING. Issue 1 (January 2016)
- Record Type:
- Journal Article
- Title:
- PREVALENCE OF RETICULAR PSEUDODRUSEN IN AGE-RELATED MACULAR DEGENERATION USING MULTIMODAL IMAGING. Issue 1 (January 2016)
- Main Title:
- PREVALENCE OF RETICULAR PSEUDODRUSEN IN AGE-RELATED MACULAR DEGENERATION USING MULTIMODAL IMAGING
- Authors:
- De Bats, Flore
Mathis, Thibaud
Mauget-Faÿsse, Martine
Joubert, Fabien
Denis, Philippe
Kodjikian, Laurent - Abstract:
- Abstract : Purpose: To determine the rate of reticular pseudodrusen (RPD) in age-related macular degeneration using multimodal imaging, including color fundus photography, the blue channel image of fundus photography, infrared reflectance, fundus autofluorescence, multicolor imaging, and spectral domain optical coherence tomography, as well as to compare the sensitivities and specificities of these modalities for detecting RPD. Methods: This prospective study included 243 eyes from 125 consecutive patients with age-related macular degeneration. They underwent fundus examination including color fundus photography, blue channel, infrared reflectance, fundus autofluorescence, multicolor imaging, and spectral domain optical coherence tomography in both eyes. To be considered as having RPD, eyes had to have reticular patterns on spectral domain optical coherence tomography in a large studied cube of 30° × 25° or on infrared reflectance with at least one other examination. Results: The mean age of the 125 patients was 81.1 years (±8.1). Eighty-six patients (68.8%) were diagnosed with RPD. Spectral domain optical coherence tomography, infrared reflectance, and multicolor imaging had the highest sensitivity (99.3, 84.6, and 87.1%, respectively) and specificity (100%). The color fundus photography, blue channel, and fundus autofluorescence had lower sensitivity to detect RPD. Conclusion: Reticular pseudodrusen is frequently associated with soft drusen in patients with age-relatedAbstract : Purpose: To determine the rate of reticular pseudodrusen (RPD) in age-related macular degeneration using multimodal imaging, including color fundus photography, the blue channel image of fundus photography, infrared reflectance, fundus autofluorescence, multicolor imaging, and spectral domain optical coherence tomography, as well as to compare the sensitivities and specificities of these modalities for detecting RPD. Methods: This prospective study included 243 eyes from 125 consecutive patients with age-related macular degeneration. They underwent fundus examination including color fundus photography, blue channel, infrared reflectance, fundus autofluorescence, multicolor imaging, and spectral domain optical coherence tomography in both eyes. To be considered as having RPD, eyes had to have reticular patterns on spectral domain optical coherence tomography in a large studied cube of 30° × 25° or on infrared reflectance with at least one other examination. Results: The mean age of the 125 patients was 81.1 years (±8.1). Eighty-six patients (68.8%) were diagnosed with RPD. Spectral domain optical coherence tomography, infrared reflectance, and multicolor imaging had the highest sensitivity (99.3, 84.6, and 87.1%, respectively) and specificity (100%). The color fundus photography, blue channel, and fundus autofluorescence had lower sensitivity to detect RPD. Conclusion: Reticular pseudodrusen is frequently associated with soft drusen in patients with age-related macular degeneration. As RPD may be rarely located only in the perifoveal area, spectral domain optical coherence tomography with a larger cube (30 × 25°) than that usually used (20 × 20°) had the highest sensitivity and specificity to detect RPD and is recommended to optimize the rate of detection. Abstract : Prospective study of 243 eyes from 125 consecutive patients with age-related macular degeneration, showing a high rate (68.8%) of reticular pseudodrusen with an original multimodal imaging protocol. Sensitivities and specificities of each imaging modality have been calculated. … (more)
- Is Part Of:
- Retina. Volume 36:Issue 1(2016:Jan.)
- Journal:
- Retina
- Issue:
- Volume 36:Issue 1(2016:Jan.)
- Issue Display:
- Volume 36, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 36
- Issue:
- 1
- Issue Sort Value:
- 2016-0036-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-01
- Subjects:
- age-related macular degeneration -- fundus autofluorescence -- infrared imaging -- multicolor imaging -- reticular pseudodrusen -- spectral domain optical coherence tomography
Retina -- Diseases -- Periodicals
Retinal Diseases
Vitreous Body
617.735 - Journal URLs:
- http://journals.lww.com/retinajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IAE.0000000000000648 ↗
- Languages:
- English
- ISSNs:
- 0275-004X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.510300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5988.xml