Threshold for diagnosing hypertension by automated office blood pressure using random sample population data. Issue 11 (November 2016)
- Record Type:
- Journal Article
- Title:
- Threshold for diagnosing hypertension by automated office blood pressure using random sample population data. Issue 11 (November 2016)
- Main Title:
- Threshold for diagnosing hypertension by automated office blood pressure using random sample population data
- Authors:
- Wohlfahrt, Peter
Cífková, Renata
Movsisyan, Narine
Kunzová, Šárka
Lešovský, Jiří
Homolka, Martin
Soška, Vladimír
Bauerová, Hana
Lopez-Jimenez, Francisco
Sochor, Ondřej - Abstract:
- Abstract : Supplemental Digital Content is available in the text Abstract : Objective: Manual office blood pressure (BP) is still recommended for diagnosing hypertension. However, its predictive value is decreased by errors in measurement technique and the white-coat effect. The errors can be eliminated by automated office BP (AOBP) measurement taking multiple readings with the participant resting quietly alone. Therefore, use of AOBP in clinical practice requires a threshold value for hypertension diagnosis. The aim of the present study was to determine an AOBP threshold corresponding to the 140/90 mmHg manual office BP using data from a large random population sample. Methods: In 2145 participants (mean age 47.3 ± 11.3 years) randomly selected from a Brno population aged 25–64 years, BP was measured using manual mercury and automated office sphygmomanometers. Results: Manual SBP (mean difference 6.39 ± 9.76 mmHg) and DBP (mean difference 2.50 ± 6.54 mmHg) were higher than the automated BP. According to polynomial regression, automated systole of 131.06 (95% confidence interval 130.43–131.70) and diastole of 85.43 (95% confidence interval 85.03–85.82) corresponded to the manual BP of 140/90 mmHg. Using this cut-off, the white-coat hypertension was present in 24% of participants with elevated manual BP, whereas 10% had masked hypertension and 11% masked uncontrolled hypertension. In individuals with masked uncontrolled hypertension, only AOBP was associated with the urinaryAbstract : Supplemental Digital Content is available in the text Abstract : Objective: Manual office blood pressure (BP) is still recommended for diagnosing hypertension. However, its predictive value is decreased by errors in measurement technique and the white-coat effect. The errors can be eliminated by automated office BP (AOBP) measurement taking multiple readings with the participant resting quietly alone. Therefore, use of AOBP in clinical practice requires a threshold value for hypertension diagnosis. The aim of the present study was to determine an AOBP threshold corresponding to the 140/90 mmHg manual office BP using data from a large random population sample. Methods: In 2145 participants (mean age 47.3 ± 11.3 years) randomly selected from a Brno population aged 25–64 years, BP was measured using manual mercury and automated office sphygmomanometers. Results: Manual SBP (mean difference 6.39 ± 9.76 mmHg) and DBP (mean difference 2.50 ± 6.54 mmHg) were higher than the automated BP. According to polynomial regression, automated systole of 131.06 (95% confidence interval 130.43–131.70) and diastole of 85.43 (95% confidence interval 85.03–85.82) corresponded to the manual BP of 140/90 mmHg. Using this cut-off, the white-coat hypertension was present in 24% of participants with elevated manual BP, whereas 10% had masked hypertension and 11% masked uncontrolled hypertension. In individuals with masked uncontrolled hypertension, only AOBP was associated with the urinary albumin–creatinine ratio, whereas there was no association with manual BP. Conclusion: AOBP of 131/85 mmHg corresponds to the manual BP of 140/90 mmHg. This value may be used as a threshold for diagnosing hypertension using AOBP. However, outcome-driven studies are required to confirm this threshold. … (more)
- Is Part Of:
- Journal of hypertension. Volume 34:Issue 11(2016:Nov.)
- Journal:
- Journal of hypertension
- Issue:
- Volume 34:Issue 11(2016:Nov.)
- Issue Display:
- Volume 34, Issue 11 (2016)
- Year:
- 2016
- Volume:
- 34
- Issue:
- 11
- Issue Sort Value:
- 2016-0034-0011-0000
- Page Start:
- 2180
- Page End:
- 2186
- Publication Date:
- 2016-11
- Subjects:
- automated office blood pressure measurement -- blood pressure -- masked hypertension -- mercury sphygmomanometer -- white coat hypertension
Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/HJH.0000000000001076 ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5995.xml