Early results of MitraClip system implantation by real-time three-dimensional speckle-tracking left ventricle analysis. Issue 11 (November 2016)
- Record Type:
- Journal Article
- Title:
- Early results of MitraClip system implantation by real-time three-dimensional speckle-tracking left ventricle analysis. Issue 11 (November 2016)
- Main Title:
- Early results of MitraClip system implantation by real-time three-dimensional speckle-tracking left ventricle analysis
- Authors:
- Scandura, Salvatore
Dipasqua, Fabio
Gargiulo, Giuseppe
Capodanno, Davide
Caggegi, Anna
Grasso, Carmelo
Mangiafico, Sarah
Pistritto, Anna Maria
Immè, Sebastiano
Chiarandà, Marta
Ministeri, Margherita
Ronsivalle, Giuseppe
Cannata, Stefano
Arcidiacono, Antonio Andrea
Capranzano, Piera
Tamburino, Corrado - Abstract:
- Abstract : Supplemental Digital Content is available in the text Abstract : Aims: To appraise the early effect of percutaneous mitral valve repair with the MitraClip system on myocardial function using real-time three-dimensional speckle-tracking echocardiography (3D-STE). Methods: Consecutive patients with moderate-to-severe or severe mitral regurgitation, undergoing mitral valve repair with the MitraClip system, were prospectively evaluated during the peri-procedural workout and follow-up. Left ventricular deformation was evaluated by a two-dimensional and 3D speckle-tracking analysis. 3D-STE acquisitions were elaborated obtaining real-time 3D global longitudinal strain evaluation, and by appraising both volumetric and hemodynamic parameters (i.e. left ventricular end-diastolic volume, left ventricular end-systolic volume, left ventricular ejection fraction, cardiac output, and stroke volume). Results: In all, 30 patients were included. At 1-month follow-up, 3D-STE analysis revealed no changes in left ventricular end-diastolic volume (162.6 ± 73.7 ml at baseline vs. 159.8 ± 64.5 ml at 1-month follow-up; P = 0.63) and a downward trend in left ventricular end-systolic volume (104.7 ± 52.0 vs. 100.1 ± 50.4 ml, respectively; P = 0.06). Left ventricular ejection fraction did not significantly increase (38.1 ± 11.3% at baseline vs. 39.4 ± 11.0% at 1-month follow-up; P = 0.20). No significant changes were reported in cardiac output (4.3 ± 2.0 l/min at baseline vs.Abstract : Supplemental Digital Content is available in the text Abstract : Aims: To appraise the early effect of percutaneous mitral valve repair with the MitraClip system on myocardial function using real-time three-dimensional speckle-tracking echocardiography (3D-STE). Methods: Consecutive patients with moderate-to-severe or severe mitral regurgitation, undergoing mitral valve repair with the MitraClip system, were prospectively evaluated during the peri-procedural workout and follow-up. Left ventricular deformation was evaluated by a two-dimensional and 3D speckle-tracking analysis. 3D-STE acquisitions were elaborated obtaining real-time 3D global longitudinal strain evaluation, and by appraising both volumetric and hemodynamic parameters (i.e. left ventricular end-diastolic volume, left ventricular end-systolic volume, left ventricular ejection fraction, cardiac output, and stroke volume). Results: In all, 30 patients were included. At 1-month follow-up, 3D-STE analysis revealed no changes in left ventricular end-diastolic volume (162.6 ± 73.7 ml at baseline vs. 159.8 ± 64.5 ml at 1-month follow-up; P = 0.63) and a downward trend in left ventricular end-systolic volume (104.7 ± 52.0 vs. 100.1 ± 50.4 ml, respectively; P = 0.06). Left ventricular ejection fraction did not significantly increase (38.1 ± 11.3% at baseline vs. 39.4 ± 11.0% at 1-month follow-up; P = 0.20). No significant changes were reported in cardiac output (4.3 ± 2.0 l/min at baseline vs. 4.0 ± 1.5 l/min at follow-up; P = 0.377) and in stroke volume (59.5 ± 25.5 ml at baseline vs. 59.9 ± 20.7 ml at follow-up; P = 0.867). On the contrary, left ventricular deformation capability significantly improved, with the real-time 3D global longitudinal strain value changing from −9.8 ± 4.1% at baseline to −11.0 ± 4.4% at follow-up ( P = 0.018). Conclusions: Accurately assessing myocardial function by the use of 3D-STE, this study reported irrelevant early changes in left ventricular size, but a positive effect on left ventricular deformation capability following mitral valve repair with the MitraClip system. These preliminary results need to be confirmed in larger series and extended to long-term follow-up. … (more)
- Is Part Of:
- Journal of cardiovascular medicine. Volume 17:Issue 11(2016:Nov.)
- Journal:
- Journal of cardiovascular medicine
- Issue:
- Volume 17:Issue 11(2016:Nov.)
- Issue Display:
- Volume 17, Issue 11 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 11
- Issue Sort Value:
- 2016-0017-0011-0000
- Page Start:
- 843
- Page End:
- 849
- Publication Date:
- 2016-11
- Subjects:
- left ventricular deformation -- MitraClip system -- mitral regurgitation -- real-time three-dimensional echocardiography -- speckle tracking
Cardiology -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cardiology -- Periodicals
Cardiovascular Diseases -- Periodicals
616.1005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=01244665-000000000-00000 ↗
http://www.jcardiovascularmedicine.com/pt/re/jcm/home.htm ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.2459/JCM.0000000000000284 ↗
- Languages:
- English
- ISSNs:
- 1558-2027
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.867300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5983.xml