Comparison of Results of Accelerated Corneal Cross-Linking With Hypo-Osmolar Riboflavin Solution Performed on Corneas Thicker and Thinner Than 400 μm. Issue 2 (February 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of Results of Accelerated Corneal Cross-Linking With Hypo-Osmolar Riboflavin Solution Performed on Corneas Thicker and Thinner Than 400 μm. Issue 2 (February 2016)
- Main Title:
- Comparison of Results of Accelerated Corneal Cross-Linking With Hypo-Osmolar Riboflavin Solution Performed on Corneas Thicker and Thinner Than 400 μm
- Authors:
- Koç, Mustafa
Uzel, Mehmet Murat
Koban, Yaran
Durukan, Irfan
Tekin, Kemal
Yılmazbaş, Pelin - Abstract:
- Abstract : Purpose: To evaluate the effect of accelerated corneal cross-linking (CXL) according to corneal thickness in keratoconus. Methods: Patients undergoing corneal CXL (9 mW/cm 2 ) with hypo-osmolar riboflavin solution were included in this study. The patients were divided into 2 groups. Group 1 included patients with corneal thickness below 400 μm (50 eyes from 45 patients), and group 2 included patients with corneal thickness above 400 μm (50 eyes from 47 patients). Visual acuity (VA), refraction, topographic values, and higher-order aberrations were evaluated in the preoperative term and postoperatively at months 1, 3, and 6. Results: The improvements in VA were significant and similar in both groups [0.25/0.19 logMAR, P = 0.130]. In group 1, the rate of decrease in spherical refraction [0.85/0.27 diopters (D), P = 0.012] and maximum keratometry (Kmax, 2.49/0.68 D, P < 0.001) was significantly higher than that in group 2. The cylindrical change was similar (0.43/0.29 D P = 0.173). Corneal thinning was higher in group 2 (25/40.4 μm P < 0.001). Anterior elevation values decreased at higher rates in group 1 (3.73/0.24 μm P < 0.001); neither group showed a significant difference in posterior elevation (−0.14/−0.4 μm P > 0.05). In group 1, all aberration values except trefoil significantly decreased, whereas in group 2 none of the aberrations decreased except the total root mean square. All higher-order aberration values decreased at significantly higher rates in group 1Abstract : Purpose: To evaluate the effect of accelerated corneal cross-linking (CXL) according to corneal thickness in keratoconus. Methods: Patients undergoing corneal CXL (9 mW/cm 2 ) with hypo-osmolar riboflavin solution were included in this study. The patients were divided into 2 groups. Group 1 included patients with corneal thickness below 400 μm (50 eyes from 45 patients), and group 2 included patients with corneal thickness above 400 μm (50 eyes from 47 patients). Visual acuity (VA), refraction, topographic values, and higher-order aberrations were evaluated in the preoperative term and postoperatively at months 1, 3, and 6. Results: The improvements in VA were significant and similar in both groups [0.25/0.19 logMAR, P = 0.130]. In group 1, the rate of decrease in spherical refraction [0.85/0.27 diopters (D), P = 0.012] and maximum keratometry (Kmax, 2.49/0.68 D, P < 0.001) was significantly higher than that in group 2. The cylindrical change was similar (0.43/0.29 D P = 0.173). Corneal thinning was higher in group 2 (25/40.4 μm P < 0.001). Anterior elevation values decreased at higher rates in group 1 (3.73/0.24 μm P < 0.001); neither group showed a significant difference in posterior elevation (−0.14/−0.4 μm P > 0.05). In group 1, all aberration values except trefoil significantly decreased, whereas in group 2 none of the aberrations decreased except the total root mean square. All higher-order aberration values decreased at significantly higher rates in group 1 ( P < 0.05). Conclusions: In thin corneas, accelerated corneal CXL provides better anatomical changes; however, the improvement in VA is similar to that in thick corneas. … (more)
- Is Part Of:
- Cornea. Volume 35:Issue 2(2016)
- Journal:
- Cornea
- Issue:
- Volume 35:Issue 2(2016)
- Issue Display:
- Volume 35, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 35
- Issue:
- 2
- Issue Sort Value:
- 2016-0035-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-02
- Subjects:
- thin cornea -- corneal cross-linking -- hypo-osmolar riboflavin solution -- higher-order aberration
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000000709 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5981.xml