Error analysis of helmholtz‐based MR‐electrical properties tomography. Issue 1 (16th November 2017)
- Record Type:
- Journal Article
- Title:
- Error analysis of helmholtz‐based MR‐electrical properties tomography. Issue 1 (16th November 2017)
- Main Title:
- Error analysis of helmholtz‐based MR‐electrical properties tomography
- Authors:
- Mandija, Stefano
Sbrizzi, Alessandro
Katscher, Ulrich
Luijten, Peter R.
van den Berg, Cornelis A.T. - Abstract:
- Abstract : Purpose: MR electrical properties tomography (MR‐EPT) aims to measure tissue electrical properties by computing spatial derivatives of measured B 1 + data. This computation is very sensitive to spatial fluctuations caused, for example, by noise and Gibbs ringing. In this work, the error arising from the computation of spatial derivatives using finite difference kernels (FD error) has been investigated. In relation to this FD error, it has also been investigated whether mitigation strategies such as Gibbs ringing correction and Gaussian apodization can be beneficial for conductivity reconstructions. Methods: Conductivity reconstructions were performed on a phantom (by means of simulations and MR measurements at 3T) and on a human brain model. The accuracy was evaluated as a function of image resolution, FD kernel size, k‐space windowing, and signal‐to‐noise ratio. The impact of mitigation strategies was also investigated. Results: The adopted small FD kernel is highly sensitive to spatial fluctuations, whereas the large FD kernel is more noise‐robust. However, large FD kernels lead to extended numerical boundary error propagation, which severely hampers the MR‐EPT reconstruction accuracy for highly spatially convoluted tissue structures such as the human brain. Mitigation strategies slightly improve the accuracy of conductivity reconstructions. For the adopted derivative kernels and the investigated scenario, MR‐EPT conductivity reconstructions show low accuracy:Abstract : Purpose: MR electrical properties tomography (MR‐EPT) aims to measure tissue electrical properties by computing spatial derivatives of measured B 1 + data. This computation is very sensitive to spatial fluctuations caused, for example, by noise and Gibbs ringing. In this work, the error arising from the computation of spatial derivatives using finite difference kernels (FD error) has been investigated. In relation to this FD error, it has also been investigated whether mitigation strategies such as Gibbs ringing correction and Gaussian apodization can be beneficial for conductivity reconstructions. Methods: Conductivity reconstructions were performed on a phantom (by means of simulations and MR measurements at 3T) and on a human brain model. The accuracy was evaluated as a function of image resolution, FD kernel size, k‐space windowing, and signal‐to‐noise ratio. The impact of mitigation strategies was also investigated. Results: The adopted small FD kernel is highly sensitive to spatial fluctuations, whereas the large FD kernel is more noise‐robust. However, large FD kernels lead to extended numerical boundary error propagation, which severely hampers the MR‐EPT reconstruction accuracy for highly spatially convoluted tissue structures such as the human brain. Mitigation strategies slightly improve the accuracy of conductivity reconstructions. For the adopted derivative kernels and the investigated scenario, MR‐EPT conductivity reconstructions show low accuracy: less than 37% of the voxels have a relative error lower than 30%. Conclusion: The numerical error introduced by the computation of spatial derivatives using FD kernels is one of the major causes of limited accuracy in Helmholtz‐based MR‐EPT reconstructions. Magn Reson Med 80:90–100, 2018. © 2017 International Society for Magnetic Resonance in Medicine. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 80:Issue 1(2018)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 80:Issue 1(2018)
- Issue Display:
- Volume 80, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 80
- Issue:
- 1
- Issue Sort Value:
- 2018-0080-0001-0000
- Page Start:
- 90
- Page End:
- 100
- Publication Date:
- 2017-11-16
- Subjects:
- MR‐EPT -- conductivity -- k‐space truncation -- differentiation kernels
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27004 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5979.xml