Safety and feasibility of stereotactic radiotherapy using computed portal radiography for canine intracranial tumors. Issue 2 (4th December 2017)
- Record Type:
- Journal Article
- Title:
- Safety and feasibility of stereotactic radiotherapy using computed portal radiography for canine intracranial tumors. Issue 2 (4th December 2017)
- Main Title:
- Safety and feasibility of stereotactic radiotherapy using computed portal radiography for canine intracranial tumors
- Authors:
- Rancilio, Nicholas J.
Bentley, R. Timothy
Plantenga, Jeannie Poulson
Parys, Magdalena M.
Crespo, Beatriz G.
Moore, George E. - Abstract:
- Abstract: Stereotactic radiotherapy is a highly conformal treatment option for intracranial and extracranial malignancies. Stereotactic radiotherapy utilizes specialized equipment specifically designed to avoid normal tissue while delivering ablative treatments with submillimeter precision and accuracy. Linear accelerator based stereotactic radiotherapy incorporates on‐board image guidance utilizing cone beam computed tomography (CT). Many institutions lack the ability to provide image guidance with cone beam CT but delivery of highly conformal treatments with submillimeter precision and accuracy is still feasible. The purpose of this retrospective, pilot study was to describe clinical outcomes for a group of dogs with neurological disease that were treated with an stereotactic radiotherapy technique utilizing intensity modulated radiation therapy, megavoltage computed portal radiography, a bite plate, thermoplastic mold, and mask based positioning system. Twelve dogs with neurological clinical signs were included. The diagnosis of intracranial tumor was made based on advanced imaging (12/12) and confirmed via histopathology (3/12). Twelve courses of stereotactic radiotherapy, utilizing three fractions of 8.0 Gy, were delivered on alternating days. Self‐resolving neurological deterioration was observed in two patients during stereotactic radiotherapy. Neurological progression free interval and median survival time were 273 days (range: 16–692 days) and 361 days (range:Abstract: Stereotactic radiotherapy is a highly conformal treatment option for intracranial and extracranial malignancies. Stereotactic radiotherapy utilizes specialized equipment specifically designed to avoid normal tissue while delivering ablative treatments with submillimeter precision and accuracy. Linear accelerator based stereotactic radiotherapy incorporates on‐board image guidance utilizing cone beam computed tomography (CT). Many institutions lack the ability to provide image guidance with cone beam CT but delivery of highly conformal treatments with submillimeter precision and accuracy is still feasible. The purpose of this retrospective, pilot study was to describe clinical outcomes for a group of dogs with neurological disease that were treated with an stereotactic radiotherapy technique utilizing intensity modulated radiation therapy, megavoltage computed portal radiography, a bite plate, thermoplastic mold, and mask based positioning system. Twelve dogs with neurological clinical signs were included. The diagnosis of intracranial tumor was made based on advanced imaging (12/12) and confirmed via histopathology (3/12). Twelve courses of stereotactic radiotherapy, utilizing three fractions of 8.0 Gy, were delivered on alternating days. Self‐resolving neurological deterioration was observed in two patients during stereotactic radiotherapy. Neurological progression free interval and median survival time were 273 days (range: 16–692 days) and 361 days (range: 25–862 days). Stereotactic radiotherapy using computed portal radiography may be a safe treatment option for dogs with intracranial tumors. … (more)
- Is Part Of:
- Veterinary radiology & ultrasound. Volume 59:Issue 2(2018)
- Journal:
- Veterinary radiology & ultrasound
- Issue:
- Volume 59:Issue 2(2018)
- Issue Display:
- Volume 59, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 59
- Issue:
- 2
- Issue Sort Value:
- 2018-0059-0002-0000
- Page Start:
- 212
- Page End:
- 220
- Publication Date:
- 2017-12-04
- Subjects:
- brain -- dogs -- port film -- positioning -- stereotactic fractionated radiotherapy
Veterinary radiology -- Periodicals
Radiologie vétérinaire -- Périodiques
Échographie vétérinaire -- Périodiques
Radiography -- Periodicals
Ultrasonography -- Periodicals
Diagnosis -- Periodicals
Veterinary Medicine -- Periodicals
Societies, Medical -- Periodicals
636.089607 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1740-8261 ↗
http://www.blackwell-synergy.com/loi/vru ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1058-8183;screen=info;ECOIP ↗
http://www.blackwell-synergy.com/loi/vru ↗ - DOI:
- 10.1111/vru.12579 ↗
- Languages:
- English
- ISSNs:
- 1058-8183
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9229.281000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5984.xml