Comparison of four techniques for spine stereotactic body radiotherapy: Dosimetric and efficiency analysis. (7th February 2018)
- Record Type:
- Journal Article
- Title:
- Comparison of four techniques for spine stereotactic body radiotherapy: Dosimetric and efficiency analysis. (7th February 2018)
- Main Title:
- Comparison of four techniques for spine stereotactic body radiotherapy: Dosimetric and efficiency analysis
- Authors:
- Aljabab, Saif
Vellayappan, Balamurugan
Vandervoort, Eric
Bahm, Jamie
Zohr, Robert
Sinclair, John
Caudrelier, Jean‐Michel
Szanto, Janos
Malone, Shawn - Abstract:
- Abstract: Purpose: The aim of this study is to compare the dosimetric differences between four techniques for spine stereotactic body radiotherapy (SBRT): CyberKnife (CK), volumetric modulated arc therapy (VMAT), and helical tomotherapy (HT) with dynamic jaws (HT‐D) and fixed jaws (HT‐F). Materials/methods: Data from 10 patients were utilized. All patients were planned for 24 Gy in two fractions, with the primary objectives being: (a) restricting the maximum dose to the cord to ≤ 17 Gy and/or cauda equina to ≤ 20 Gy, and (b) to maximize the clinical target volume (CTV) to receive the prescribed dose. Treatment plans were generated by separate dosimetrists and then compared using velocity AI. Parameters of comparison include target volume coverage, conformity index (CI), gradient index (GI), homogeneity index (HI), treatment time (TT) per fraction, and monitor units (MU) per fraction. Results: PTV D2 and D5 were significantly higher for CK compared to VMAT, HT‐F, and HT‐D ( P < 0.001). The average volume of CTV receiving the prescription dose (CTV D95) was significantly less for VMAT compared to CK, HT‐F and HT‐D ( P = 0.036). CI improved for CK (0.69), HT‐F (0.66), and HT‐D (0.67) compared to VMAT (0.52) ( P = 0.013). CK (41.86) had the largest HI compared to VMAT (26.99), HT‐F (20.69), and HT‐D (21.17) ( P < 0.001). GI was significantly less for CK (3.96) compared to VMAT (6.76) ( P = 0.001). Likewise, CK (62.4 min, 14059 MU) had the longest treatment time and MU perAbstract: Purpose: The aim of this study is to compare the dosimetric differences between four techniques for spine stereotactic body radiotherapy (SBRT): CyberKnife (CK), volumetric modulated arc therapy (VMAT), and helical tomotherapy (HT) with dynamic jaws (HT‐D) and fixed jaws (HT‐F). Materials/methods: Data from 10 patients were utilized. All patients were planned for 24 Gy in two fractions, with the primary objectives being: (a) restricting the maximum dose to the cord to ≤ 17 Gy and/or cauda equina to ≤ 20 Gy, and (b) to maximize the clinical target volume (CTV) to receive the prescribed dose. Treatment plans were generated by separate dosimetrists and then compared using velocity AI. Parameters of comparison include target volume coverage, conformity index (CI), gradient index (GI), homogeneity index (HI), treatment time (TT) per fraction, and monitor units (MU) per fraction. Results: PTV D2 and D5 were significantly higher for CK compared to VMAT, HT‐F, and HT‐D ( P < 0.001). The average volume of CTV receiving the prescription dose (CTV D95) was significantly less for VMAT compared to CK, HT‐F and HT‐D ( P = 0.036). CI improved for CK (0.69), HT‐F (0.66), and HT‐D (0.67) compared to VMAT (0.52) ( P = 0.013). CK (41.86) had the largest HI compared to VMAT (26.99), HT‐F (20.69), and HT‐D (21.17) ( P < 0.001). GI was significantly less for CK (3.96) compared to VMAT (6.76) ( P = 0.001). Likewise, CK (62.4 min, 14059 MU) had the longest treatment time and MU per fraction compared to VMAT (8.5 min, 9764 MU), HT‐F (13 min, 10822 MU), and HT‐D (13.5 min, 11418 MU) ( P < 0.001). Conclusion: Both CK and HT plans achieved conformal target coverage while respecting cord tolerance. Dose heterogeneity was significantly larger in CK. VMAT required the least treatment time and MU output, but had the least steep GI, CI, and target coverage. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 19:Number 2(2018)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 19:Number 2(2018)
- Issue Display:
- Volume 19, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 19
- Issue:
- 2
- Issue Sort Value:
- 2018-0019-0002-0000
- Page Start:
- 160
- Page End:
- 167
- Publication Date:
- 2018-02-07
- Subjects:
- conformity index -- cyberknife -- dosimetric evaluation -- dynamic wedges -- spine SBRT -- tomotherapy -- VMAT
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12271 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5961.xml