MRI monitoring of focused ultrasound sonications near metallic hardware. Issue 1 (7th December 2017)
- Record Type:
- Journal Article
- Title:
- MRI monitoring of focused ultrasound sonications near metallic hardware. Issue 1 (7th December 2017)
- Main Title:
- MRI monitoring of focused ultrasound sonications near metallic hardware
- Authors:
- Weber, Hans
Ghanouni, Pejman
Pascal‐Tenorio, Aurea
Pauly, Kim Butts
Hargreaves, Brian A. - Abstract:
- Abstract : Purpose: To explore the temperature‐induced signal change in two‐dimensional multi‐spectral imaging (2DMSI) for fast thermometry near metallic hardware to enable MR‐guided focused ultrasound surgery (MRgFUS) in patients with implanted metallic hardware. Method: 2DMSI was optimized for temperature sensitivity and applied to monitor focus ultrasound surgery (FUS) sonications near metallic hardware in phantoms and ex vivo porcine muscle tissue. Further, we evaluated its temperature sensitivity for in vivo muscle in patients without metallic hardware. In addition, we performed a comparison of temperature sensitivity between 2DMSI and conventional proton‐resonance‐frequency‐shift (PRFS) thermometry at different distances from metal devices and different signal‐to‐noise ratios (SNR). Results: 2DMSI thermometry enabled visualization of short ultrasound sonications near metallic hardware. Calibration using in vivo muscle yielded a constant temperature sensitivity for temperatures below 43 °C. For an off‐resonance coverage of ± 6 kHz, we achieved a temperature sensitivity of 1.45%/K, resulting in a minimum detectable temperature change of ∼2.5 K for an SNR of 100 with a temporal resolution of 6 s per frame. Conclusion: The proposed 2DMSI thermometry has the potential to allow MR‐guided FUS treatments of patients with metallic hardware and therefore expand its reach to a larger patient population. Magn Reson Med 80:259–271, 2018. © 2017 International Society for MagneticAbstract : Purpose: To explore the temperature‐induced signal change in two‐dimensional multi‐spectral imaging (2DMSI) for fast thermometry near metallic hardware to enable MR‐guided focused ultrasound surgery (MRgFUS) in patients with implanted metallic hardware. Method: 2DMSI was optimized for temperature sensitivity and applied to monitor focus ultrasound surgery (FUS) sonications near metallic hardware in phantoms and ex vivo porcine muscle tissue. Further, we evaluated its temperature sensitivity for in vivo muscle in patients without metallic hardware. In addition, we performed a comparison of temperature sensitivity between 2DMSI and conventional proton‐resonance‐frequency‐shift (PRFS) thermometry at different distances from metal devices and different signal‐to‐noise ratios (SNR). Results: 2DMSI thermometry enabled visualization of short ultrasound sonications near metallic hardware. Calibration using in vivo muscle yielded a constant temperature sensitivity for temperatures below 43 °C. For an off‐resonance coverage of ± 6 kHz, we achieved a temperature sensitivity of 1.45%/K, resulting in a minimum detectable temperature change of ∼2.5 K for an SNR of 100 with a temporal resolution of 6 s per frame. Conclusion: The proposed 2DMSI thermometry has the potential to allow MR‐guided FUS treatments of patients with metallic hardware and therefore expand its reach to a larger patient population. Magn Reson Med 80:259–271, 2018. © 2017 International Society for Magnetic Resonance in Medicine. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 80:Issue 1(2018)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 80:Issue 1(2018)
- Issue Display:
- Volume 80, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 80
- Issue:
- 1
- Issue Sort Value:
- 2018-0080-0001-0000
- Page Start:
- 259
- Page End:
- 271
- Publication Date:
- 2017-12-07
- Subjects:
- multi‐spectral imaging -- thermometry -- proton resonance frequency shift -- metallic implants -- susceptibility artifact -- focused ultrasound
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27034 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5966.xml