Filter-extruded liposomes revisited: a study into size distributions and morphologies in relation to lipid-composition and process parameters. (2nd January 2016)
- Record Type:
- Journal Article
- Title:
- Filter-extruded liposomes revisited: a study into size distributions and morphologies in relation to lipid-composition and process parameters. (2nd January 2016)
- Main Title:
- Filter-extruded liposomes revisited: a study into size distributions and morphologies in relation to lipid-composition and process parameters
- Authors:
- Hinna, Askell
Steiniger, Frank
Hupfeld, Stefan
Stein, Paul
Kuntsche, Judith
Brandl, Martin - Abstract:
- Abstract: Filter-extrusion is a widely used technique for down-sizing of phospholipid vesicles. In order to gain a detailed insight into size and size distributions of filter-extruded vesicles composed of egg phosphatidyl-choline (with varying fractions of cholesterol) – in relation to extrusion-parameters (pore-size, number of filter passages, and flow-rate), flow field-flow fractionation in conjunction with multi-angle laser light scattering (AF4-MALLS, Wyatt Technology Corp., Santa Barbara, CA) was employed. Liposome size-distributions determined by AF4-MALLS were compared with those of dynamic light scattering and correlated with cryo-transmission electron microscopy and 31 P-NMR-analysis of lamellarity. Both the mean size of liposome and the width of size distribution were found to decrease with sequential extrusion through smaller pore size filters, starting at a size range of ≈70–415 nm upon repeated extrusion through 400 nm pore-filters, eventually ending with a size range from ≈30 to 85 nm upon extrusion through 30 nm pore size filters. While for small pores sizes (50 nm), increased flow rates resulted in smaller vesicles, no significant influence of flow rate on mean vesicle size was seen with larger pores. Cholesterol at increasing mol fractions up to 0.45 yielded bigger vesicles (at identical process conditions). For a cholesterol mol fraction of 0.5 in combination with small filter pore size, a bimodal size distribution was seen indicating cholesterolAbstract: Filter-extrusion is a widely used technique for down-sizing of phospholipid vesicles. In order to gain a detailed insight into size and size distributions of filter-extruded vesicles composed of egg phosphatidyl-choline (with varying fractions of cholesterol) – in relation to extrusion-parameters (pore-size, number of filter passages, and flow-rate), flow field-flow fractionation in conjunction with multi-angle laser light scattering (AF4-MALLS, Wyatt Technology Corp., Santa Barbara, CA) was employed. Liposome size-distributions determined by AF4-MALLS were compared with those of dynamic light scattering and correlated with cryo-transmission electron microscopy and 31 P-NMR-analysis of lamellarity. Both the mean size of liposome and the width of size distribution were found to decrease with sequential extrusion through smaller pore size filters, starting at a size range of ≈70–415 nm upon repeated extrusion through 400 nm pore-filters, eventually ending with a size range from ≈30 to 85 nm upon extrusion through 30 nm pore size filters. While for small pores sizes (50 nm), increased flow rates resulted in smaller vesicles, no significant influence of flow rate on mean vesicle size was seen with larger pores. Cholesterol at increasing mol fractions up to 0.45 yielded bigger vesicles (at identical process conditions). For a cholesterol mol fraction of 0.5 in combination with small filter pore size, a bimodal size distribution was seen indicating cholesterol micro-crystallites. Finally, a protocol is suggested to prepare large (∼ 300 nm) liposomes with rather narrow size distribution, based on the filter extrusion at defined flow-rates in combination with freeze-/thaw-cycling and bench-top centrifugation. … (more)
- Is Part Of:
- Journal of liposome research. Volume 26:Number 1(2016)
- Journal:
- Journal of liposome research
- Issue:
- Volume 26:Number 1(2016)
- Issue Display:
- Volume 26, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 26
- Issue:
- 1
- Issue Sort Value:
- 2016-0026-0001-0000
- Page Start:
- 11
- Page End:
- 20
- Publication Date:
- 2016-01-02
- Subjects:
- Cryo transmission electron microscopy -- flow field-flow fractionation -- lamellarity -- multi-angle light scattering
Liposomes -- Periodicals
Liposomes -- Periodicals
575.57 - Journal URLs:
- http://informahealthcare.com/loi/lpr ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/08982104.2015.1022556 ↗
- Languages:
- English
- ISSNs:
- 0898-2104
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.505000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5947.xml