Diagnostic performance of coronary CT angiography carried out with a novel whole-heart coverage high-definition CT scanner in patients with high heart rate. (15th April 2018)
- Record Type:
- Journal Article
- Title:
- Diagnostic performance of coronary CT angiography carried out with a novel whole-heart coverage high-definition CT scanner in patients with high heart rate. (15th April 2018)
- Main Title:
- Diagnostic performance of coronary CT angiography carried out with a novel whole-heart coverage high-definition CT scanner in patients with high heart rate
- Authors:
- Andreini, Daniele
Mushtaq, Saima
Pontone, Gianluca
Conte, Edoardo
Guglielmo, Marco
Annoni, Andrea
Baggiano, Andrea
Formenti, Alberto
Ditali, Valentina
Mancini, Maria Elisabetta
Zanchi, Simone
Melotti, Eleonora
Trabattoni, Daniela
Montorsi, Piero
Ravagnani, Paolo Mario
Fiorentini, Cesare
Bartorelli, Antonio L.
Pepi, Mauro - Abstract:
- Abstract: Background: Aim of the study was to evaluate image quality, radiation exposure and diagnostic accuracy of coronary CT angiography (CCTA) performed with a novel cardiac CT scanner in patients with very high heart rate (HR). Methods: We prospectively enrolled 202 patients (111 men, mean age 66 ± 8 years) with suspected coronary artery disease who underwent CCTA with a whole-organ volumetric CT scanner. The HR during the scan was ≥ 80 bpm in 100 patients (Group 1), while it was ≤ 65 bpm in the remaining 102 patients (Group 2). In all patients, image quality score and coronary interpretability were evaluated and effective dose (ED) was recorded. In 86 of the 202 enrolled patients (40 patients in Group 1, 46 patients in Group 2) who were referred for a clinically indicated invasive coronary angiography (ICA) within 6 months, diagnostic accuracy of CCTA vs. ICA was evaluated. Results: Mean image quality and coronary interpretability were very high in both Groups (Likert = 3.35 vs. 3.39 and 97.3% [1542/1584 segments] and 98% [1569/1600 segments] in Group 1 and Group 2, respectively). Mean ED was lower in Group 2 (1.1 ± 0.5 mSv) compared to Group 1 (2.9 ± 1.6 mSv). In Group 1, sensitivity and specificity of CCTA for detection of > 50% stenosis vs. ICA were 95.2% and 98.9% in a segment-based analysis and 100% and 81.8% in a patient-based analysis, respectively. Conclusions: The whole organ high-definition CT scanner allows evaluating coronary arteries in patients with highAbstract: Background: Aim of the study was to evaluate image quality, radiation exposure and diagnostic accuracy of coronary CT angiography (CCTA) performed with a novel cardiac CT scanner in patients with very high heart rate (HR). Methods: We prospectively enrolled 202 patients (111 men, mean age 66 ± 8 years) with suspected coronary artery disease who underwent CCTA with a whole-organ volumetric CT scanner. The HR during the scan was ≥ 80 bpm in 100 patients (Group 1), while it was ≤ 65 bpm in the remaining 102 patients (Group 2). In all patients, image quality score and coronary interpretability were evaluated and effective dose (ED) was recorded. In 86 of the 202 enrolled patients (40 patients in Group 1, 46 patients in Group 2) who were referred for a clinically indicated invasive coronary angiography (ICA) within 6 months, diagnostic accuracy of CCTA vs. ICA was evaluated. Results: Mean image quality and coronary interpretability were very high in both Groups (Likert = 3.35 vs. 3.39 and 97.3% [1542/1584 segments] and 98% [1569/1600 segments] in Group 1 and Group 2, respectively). Mean ED was lower in Group 2 (1.1 ± 0.5 mSv) compared to Group 1 (2.9 ± 1.6 mSv). In Group 1, sensitivity and specificity of CCTA for detection of > 50% stenosis vs. ICA were 95.2% and 98.9% in a segment-based analysis and 100% and 81.8% in a patient-based analysis, respectively. Conclusions: The whole organ high-definition CT scanner allows evaluating coronary arteries in patients with high HR with excellent image quality, coronary interpretability and low radiation exposure. … (more)
- Is Part Of:
- International journal of cardiology. Volume 257(2018)
- Journal:
- International journal of cardiology
- Issue:
- Volume 257(2018)
- Issue Display:
- Volume 257, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 257
- Issue:
- 2018
- Issue Sort Value:
- 2018-0257-2018-0000
- Page Start:
- 325
- Page End:
- 331
- Publication Date:
- 2018-04-15
- Subjects:
- Cardiac computed tomography angiography -- Coronary artery disease -- High heart rate
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2017.10.084 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5943.xml